Abstract

This report describes a new, automated chromatographic procedure eliminating carbohydrates from amino acid samples prior to their analysis by anion-exchange chromatography and integrated amperometric detection. In the first step, a sample is brought onto a short cation-exchange column (trap column) in hydrogen form. Carbohydrates are passing through this column, while only amino acids are retained. Subsequently, the cation-exchange column, holding the amino acid fraction, is switched in-line with the gradient pump and separator column. The mobile phase used at the beginning of the separation (NaOH; pH 12.7) transfers amino acids from the trap column onto the anion-exchange column and the amino acid separation is completed without any interference by carbohydrates. All common amino acids are recovered following the carbohydrate removal step. The average value of their recovery is 88.1%. The calibration plots were tested between 12.5 and 500 pmol (amounts injected). The mean value of correlation coefficients of calibration plots was calculated as 0.99. The mean value of relative standard deviations from five replicates was 3.9%. The usefulness of the method is illustrated with two chromatograms of a carrot juice sample obtained before and after the in-line removal of carbohydrates.

摘要

相似文献

1
Simplified in-line sample preparation for amino acid analysis in carbohydrate containing samples.
J Chromatogr B Biomed Sci Appl. 2001 Jul 15;758(2):189-96. doi: 10.1016/s0378-4347(01)00179-7.
3
Sample preparation for amino acid determination by integrated pulsed amperometric detection in foods.
Anal Biochem. 2002 Nov 15;310(2):171-8. doi: 10.1016/s0003-2697(02)00283-x.
5
Analysis of amino acid-carbohydrate mixtures by anion exchange chromatography and integrated pulsed amperometric detection.
J Biochem Biophys Methods. 2004 Sep 30;60(3):191-203. doi: 10.1016/j.jbbm.2004.01.003.

引用本文的文献

1
Carbohydrate Background Removal in Metabolomics Samples.
Anal Chem. 2018 Dec 18;90(24):14100-14104. doi: 10.1021/acs.analchem.8b04482. Epub 2018 Dec 3.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验