Prakash U, Wigderowitz C A, McGurty D W, Rowley D I
Department of Orthopaedic and Trauma Surgery, University of Dundee, Scotland, UK.
J Bone Joint Surg Br. 2001 Aug;83(6):819-24. doi: 10.1302/0301-620x.83b6.11349.
Tibiofemoral alignment has a direct correlation with the survival of total knee arthroplasty. Traditionally, it has been measured using a goniometer on radiographs. We describe new software which measures this alignment on scanned radiographs by automatically detecting bones in the image. Two surgeons used conventional methods and two clerical officers used the computerised routine to assess 58 radiographs of the knee on two occasions. There were no significant differences between any of the paired comparisons. The largest mean difference detected was 1.19 degrees. Across all comparisons, the mean correlation was 0.755. A standardised routine for measuring tibiofemoral alignment was the greatest factor in reducing error in our study. These results show that non-medical staff can reliably use the software to measure tibiofemoral alignment. It has the potential to measure all the parameters recommended by the Knee Society.
胫股关节对线与全膝关节置换术的生存率直接相关。传统上,它是通过在X线片上使用角度计来测量的。我们介绍了一种新软件,该软件通过自动检测图像中的骨骼来在扫描的X线片上测量这种对线情况。两名外科医生使用传统方法,两名文职人员使用计算机程序在两个不同时间评估了58张膝关节X线片。在任何配对比较中均无显著差异。检测到的最大平均差异为1.19度。在所有比较中,平均相关性为0.755。在我们的研究中,测量胫股关节对线的标准化程序是减少误差的最大因素。这些结果表明,非医务人员可以可靠地使用该软件来测量胫股关节对线。它有潜力测量膝关节协会推荐的所有参数。