• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Practical aspects of in situ 16O (gamma,n) 15O activation using a conventional medical accelerator for the purpose of perfusion imaging.

作者信息

Oldham M, Sapareto S A, Li X A, Allen J, Sutlief S, Wong O C, Wong J W

机构信息

Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, Michigan 48073, USA.

出版信息

Med Phys. 2001 Aug;28(8):1669-78. doi: 10.1118/1.1386777.

DOI:10.1118/1.1386777
PMID:11548936
Abstract

We report investigations into the feasibility of generating radioactive oxygen (15O, a positron emitter, with half-life 2.05 min) using a tuned Elekta SL25 accelerator, for the end purpose of imaging tumor perfusion. 15O is produced by the "gamma, neutron," (gamma,n) reaction between high-energy photons and normal oxygen (16O) in the body. As most in vivo 16O is bound in water molecules the 15O radio-marker is produced in proportion to water content in tissue. Imaging the washout of the 15O distribution using sensitive positron-emission-tomography (PET) technology can yield spatial information about blood perfusion in the tissue. The aim of this article was to determine the amount of 15O activity that could be produced by the tuned medical accelerator. A further aim was to model the activation process using Monte Carlo and to investigate ways to optimize the amount of 15O that could be generated. Increased activation was achieved by (i) tuning the beam to give higher-energy electrons incident on the target of the accelerator, (ii) increasing dose rate by removing the conventional filtration in the beam and reducing the source to object distance, and (iii) reducing low-energy photons by means of a carbon block absorber. The activity per-unit-dose produced by the tuned beam was measured by irradiating spheres of water to known doses and placing the spheres in a calibrated coincidence-counting apparatus. Peak energy of the tuned bremsstrahlung beam was estimated at 29 MeV, and generated activity up to 0.24/microCi/cc/3Gy in water. The measured amount of 15O agreed to within 10% of the prediction from the Monte-Carlo-computed spectrum, indicating reasonable ability to model the activation process. The optimal thickness of the carbon absorber was found to be about 25 cm. The insertion of a carbon absorber improved spectral quality for activation purposes but at the cost of reduced dose rate. In conclusion, the viability of generating 15O with an Elekta SL25 has been demonstrated. In conjunction with recent advances in high-sensitivity portable PET imaging devices, real potential exists for imaging in situ activated 15O washout as a surrogate measurement of macroscopic tumor perfusion.

摘要

相似文献

1
Practical aspects of in situ 16O (gamma,n) 15O activation using a conventional medical accelerator for the purpose of perfusion imaging.
Med Phys. 2001 Aug;28(8):1669-78. doi: 10.1118/1.1386777.
2
Measurement of activity yields for 12C(gamma, n)11C, 14N(gamma, n)13N, and 16O(gamma, n)15O reactions as a function of electron beam energy and angle from the electron beam using thick target produced bremsstrahlung.利用厚靶产生的轫致辐射,测量作为电子束能量和相对于电子束角度的函数的\(^{12}C(\gamma,n)^{11}C\)、\(^{14}N(\gamma,n)^{13}N\)和\(^{16}O(\gamma,n)^{15}O\)反应的活度产额。
Med Phys. 1983 Mar-Apr;10(2):147-54. doi: 10.1118/1.595295.
3
PHITS simulations of absorbed dose out-of-field and neutron energy spectra for ELEKTA SL25 medical linear accelerator.ELEKTA SL25医用直线加速器的野外吸收剂量和中子能谱的PHITS模拟。
Phys Med Biol. 2015 Jun 21;60(12):N261-70. doi: 10.1088/0031-9155/60/12/N261. Epub 2015 Jun 9.
4
Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.线性加速器在有和没有均整滤过器情况下工作时,射野内和射野外剂量分布的蒙特卡罗研究
Med Phys. 2012 Aug;39(8):5194-203. doi: 10.1118/1.4738963.
5
Air activation by an electron synchrotron.电子同步加速器对空气的激活作用。
Health Phys. 1982 Jul;43(1):3-12. doi: 10.1097/00004032-198207000-00001.
6
15O and 11C production in neutron radiotherapy patients.中子放射治疗患者体内15O和11C的生成
Phys Med Biol. 1987 Dec;32(12):1559-67. doi: 10.1088/0031-9155/32/12/003.
7
Accelerator-based neutron brachytherapy.基于加速器的中子近距离治疗。
Med Phys. 2002 Jan;29(1):15-25. doi: 10.1118/1.1427308.
8
Permanent-magnet energy spectrometer for electron beams from radiotherapy accelerators.用于放射治疗加速器电子束的永磁能量谱仪。
Med Phys. 2015 Sep;42(9):5517-29. doi: 10.1118/1.4928674.
9
Monte carlo electron source model validation for an Elekta Precise linac.蒙特卡罗电子源模型验证用于 Elekta Precise 直线加速器。
Med Phys. 2011 May;38(5):2366-73. doi: 10.1118/1.3570579.
10
Activation processes in a medical linear accelerator and spatial distribution of activation products.医用直线加速器中的活化过程及活化产物的空间分布。
Phys Med Biol. 2006 Dec 21;51(24):N461-6. doi: 10.1088/0031-9155/51/24/N02. Epub 2006 Nov 30.