Combe E C, Cohen B D, Cummings K
Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota School of Dentistry, Minneapolis 55455, USA.
Int Endod J. 2001 Sep;34(6):447-51. doi: 10.1046/j.1365-2591.2001.00415.x.
This study was undertaken to evaluate which materials were in the alpha-form of gutta-percha as claimed, and which were in the more conventional beta-form, and to explore the effect of heating on the materials.
Samples of gutta-percha without chemical additives, and dental gutta-percha formulations which included (i) two products previously studied; (ii) 12 newer products; and (iii) one newer product that had been stored at high temperature, were analysed by simultaneous differential thermal analysis and thermogravimetry.
It was found that only four of the newer materials contained the alpha-form; all the rest comprised beta-gutta-percha. No weight loss was found for any material under the conditions of the present experiments. A typical heating cycle up to 130 degrees C caused changes in material behaviour - that is, on reheating fewer endothermic peaks were present. Storage of gutta-percha samples for 10 years under ambient temperature and storage in a heater at 80 degrees C appeared to have no effect on properties.
It was concluded that heating dental gutta-percha to 130 degrees C causes physical changes; this was not seen with chemically pure gutta-percha. The presence of additives in the dental samples altered material behaviour.
本研究旨在评估哪些材料如宣称的那样为α型牙胶,哪些为更常见的β型牙胶,并探究加热对这些材料的影响。
对不含化学添加剂的牙胶样本以及牙科牙胶配方进行分析,其中包括(i)之前研究过的两种产品;(ii)12种新产品;(iii)一种在高温下储存过的新产品,采用同步差示热分析和热重分析法进行分析。
发现只有四种新材料含有α型;其余均为β型牙胶。在本实验条件下,未发现任何材料有重量损失。典型的加热至130摄氏度的循环会导致材料行为发生变化——即再次加热时吸热峰减少。牙胶样本在环境温度下储存10年以及在80摄氏度的加热器中储存似乎对其性能没有影响。
得出结论,将牙科牙胶加热至130摄氏度会导致物理变化;化学纯牙胶则未观察到这种情况。牙科样本中添加剂的存在改变了材料行为。