Abstract

BACKGROUND

A new generation of subsecond multi-slice computed tomography (MSCT) scanners, which allow complete coronary coverage, are becoming widely available. We investigated the potential value of MSCT angiography in a range of coronary disorders.

METHODS

We studied 35 patients, including 11 who had undergone percutaneous transluminal coronary angioplasty and four who had had coronary-artery bypass grafts, by both MSCT and conventional coronary angiography. After intravenous injection of a non-ionic contrast medium with high iodine content, the entire heart was scanned within a single breath-hold. The total examination time was no more than 20 min. The retrospective electrocardiographically gated reconstruction source images and three-dimensional reconstructed volumes were analysed by two investigators, unaware of the results of conventional angiography.

FINDINGS

In the 31 patients without previous coronary surgery, 173 (73%) of the 237 proximal and middle coronary segments were assessable. In the assessable segments, 17 of 21 significant stenoses (>50% reduction of vessel diameter) were correctly diagnosed. The non-assessable segments included four lesions. Misinterpretations were mainly the result of severe calcification of the vessel wall. Segments with implanted stents were poorly visualised, but stent patency could be assessed in all cases. Of the 17 segments of bypass grafts, 15 were assessable and four of five graft lesions were detected. Two cases of anomalous coronary anatomy could be visualised well.

INTERPRETATION

These preliminary data suggest that MSCT allows non-invasive imaging of coronary-artery stenoses and has potential to develop into a reliable clinical technique.

摘要

背景

新一代亚秒级多层螺旋计算机断层扫描(MSCT)扫描仪可实现冠状动脉的完整覆盖,现已广泛应用。我们研究了MSCT血管造影在一系列冠状动脉疾病中的潜在价值。

方法

我们对35例患者进行了研究,其中包括11例行经皮腔内冠状动脉成形术的患者和4例行冠状动脉旁路移植术的患者,同时采用MSCT和传统冠状动脉造影检查。静脉注射高碘含量的非离子型造影剂后,在一次屏气过程中对整个心脏进行扫描。总检查时间不超过20分钟。由两名不知传统血管造影结果的研究人员对回顾性心电门控重建源图像和三维重建容积进行分析。

结果

在31例未曾接受过冠状动脉手术的患者中,237个冠状动脉近段和中段节段中有173个(73%)可进行评估。在可评估节段中,21个显著狭窄(血管直径减少>50%)中的17个被正确诊断。不可评估节段包括4个病变。误判主要是由于血管壁严重钙化所致。植入支架的节段显示不佳,但所有病例均可评估支架通畅情况。在17个旁路移植节段中,15个可进行评估,5个移植病变中的4个被检测到。2例冠状动脉解剖异常情况显示良好。

解读

这些初步数据表明,MSCT可对冠状动脉狭窄进行无创成像,并有潜力发展成为一种可靠的临床技术。