Nadol J B, Shiao J Y, Burgess B J, Ketten D R, Eddington D K, Gantz B J, Kos I, Montandon P, Coker N J, Roland J T, Shallop J K
Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston 02114, USA.
Ann Otol Rhinol Laryngol. 2001 Sep;110(9):883-91. doi: 10.1177/000348940111000914.
The insertion of an intrascalar electrode array during cochlear implantation causes immediate damage to the inner ear and may result in delayed onset of additional damage that may interfere with neuronal stimulation. To date, there have been reports on fewer than 50 temporal bone specimens from patients who had undergone implantation during life. The majority of these were single-channel implants, whereas the majority of implants inserted today are multichannel systems. This report presents the histopathologic findings in temporal bones from 8 individuals who in life had undergone multichannel cochlear implantation, with particular attention to the type and location of trauma and to long-term changes within the cochlea. The effect of these changes on spiral ganglion cell counts and the correlation between speech comprehension and spiral ganglion cell counts were calculated. In 4 of the 8 cases, the opposite, unimplanted ear was available for comparison. In 3 of the 4 cases, there was no significant difference between the spiral ganglion cell counts on the implanted and unimplanted sides. In addition, in this series of 8 cases, there was an apparent negative correlation between residual spiral ganglion cell count and hearing performance during life as measured by single-syllable word recognition. This finding suggests that abnormalities in the central auditory pathways are at least as important as spiral ganglion cell loss in limiting the performance of implant users.
人工耳蜗植入过程中插入鼓阶电极阵列会立即对内耳造成损伤,并可能导致额外损伤的延迟发生,这可能会干扰神经元刺激。迄今为止,关于生前接受植入手术患者的颞骨标本报告不足50例。其中大多数是单通道植入物,而如今植入的大多数是多通道系统。本报告展示了8例生前接受多通道人工耳蜗植入患者颞骨的组织病理学发现,特别关注创伤的类型和位置以及耳蜗内的长期变化。计算了这些变化对螺旋神经节细胞计数的影响以及言语理解与螺旋神经节细胞计数之间的相关性。在8例中的4例中,对侧未植入的耳朵可用于比较。在4例中的3例中,植入侧和未植入侧的螺旋神经节细胞计数之间没有显著差异。此外,在这一系列8例中,通过单音节单词识别测量的生前残余螺旋神经节细胞计数与听力表现之间存在明显的负相关。这一发现表明,在限制植入使用者的表现方面,中枢听觉通路的异常至少与螺旋神经节细胞丢失同样重要。