Suppr超能文献

使用波长为10.6微米和9.55微米的二氧化碳激光进行伤口愈合的比较。

Comparison of wound healing using the CO2 laser at 10.6 microm and 9.55 microm.

作者信息

Converse G M, Ries W R, Reinisch L

机构信息

Vanderbilt Bill Wilkerson Center for Otolaryngology and Communicative Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.

出版信息

Laryngoscope. 2001 Jul;111(7):1231-6. doi: 10.1097/00005537-200107000-00017.

Abstract

OBJECTIVES/HYPOTHESIS: The wound healing characteristics of incisions made with the short pulsed CO2 laser tuned to 9.55 microm versus the traditional 10.6 microm were investigated. Previous studies have shown that at 9.55 microm, collagen is targeted more selectively than at 10.6 microm, which results in decreased acute thermal injury patterns. This study investigates the difference in wound healing over time between lasers and compares laser incisions with cold knife techniques.

STUDY DESIGN

Randomized controlled trial using a porcine model.

METHODS

Tissue from 10.6-microm and 9.55-microm incisions of 10 piglets was evaluated with histological analysis and tensiometry at 3, 7, 14, and 21 days postoperatively. A Bonferroni-Dunn corrected analysis of variance analysis at a 95% significance level was used to compare the effect of wavelength.

RESULTS

The results demonstrate that although knife incisions are consistently stronger than laser incisions, the 9.55-microm CO2 laser incisions are no stronger than incisions made with the conventional 10.6-microm laser. Furthermore, histological analysis shows no difference in lateral thermal damage between lasers at 3, 7, 14, and 21 days postoperatively. The progression of collagen formation and inflammation does not differ over time.

CONCLUSION

This study of wound healing using a porcine model demonstrates that the 9.55-microm CO2 laser does not demonstrate an improvement in wound healing over the traditional 10.6-microm CO2 laser. These results may be secondary to the common explosive vaporization mechanism produced by both lasers in the infrared spectrum.

摘要

目的/假设:研究调谐至9.55微米的短脉冲二氧化碳激光与传统的10.6微米激光所做切口的伤口愈合特性。先前的研究表明,在9.55微米时,胶原蛋白比在10.6微米时更具选择性地被靶向,这导致急性热损伤模式减少。本研究调查了不同激光随时间的伤口愈合差异,并将激光切口与冷刀技术进行比较。

研究设计

使用猪模型的随机对照试验。

方法

对10只仔猪的10.6微米和9.55微米切口组织在术后3天、7天、14天和21天进行组织学分析和张力测定评估。采用在95%显著性水平下的Bonferroni-Dunn校正方差分析来比较波长的影响。

结果

结果表明,虽然刀切口始终比激光切口更强,但9.55微米二氧化碳激光切口并不比传统的10.6微米激光切口更强。此外,组织学分析显示,术后3天、7天、14天和21天,不同激光之间的侧向热损伤没有差异。胶原蛋白形成和炎症的进展随时间没有差异。

结论

这项使用猪模型的伤口愈合研究表明,9.55微米二氧化碳激光在伤口愈合方面并不比传统的10.6微米二氧化碳激光有改善。这些结果可能是由于两种激光在红外光谱中产生的常见爆炸汽化机制所致。