Zhang X, Lu Y, Wang W
Department of Radiology, China-Japan Friendship Hospital, Beijing 100029, China.
Zhonghua Yi Xue Za Zhi. 2001 Aug 25;81(16):968-70.
To evaluate the clinical application of MR-guided aspiration biopsy of liver lesions.
MR-guided aspiration biopsy of liver lesions with 0.5 T Conventional MR system and 19 gauge MRI-compatible aspiration needle was performed in 13 patients. For MR guidance, fast gradient echo sequence or fast spin echo sequence was used.
MR-guided aspiration liver biopsy was performed successfully without any complication on all patients. The accurate needle puncture rate was 100%, accurate diagnosis rate 92.3%, and false negative rate 7.7%.
MR-guided transcutaneous aspiration biopsy of liver lesions is a safe, accurate and effective method for diagnosis and differential diagnosis.