Taupitz Matthias, Schnorr Jörg, Wagner Susanne, Abramjuk Claudia, Pilgrimm Herbert, Kivelitz Dietmar, Schink Tania, Hansel Jörg, Laub Gerhard, Hünigen Hanna, Hamm Bernd
Department of Radiology, Institute for Medical Biometry, Charité, Medizinische Fakultät, Humboldt-Universität zu Berlin, Schumannstrasse 20/21, 10098 Berlin, Germany.
Radiology. 2002 Jan;222(1):120-6. doi: 10.1148/radiol.2221001452.
To evaluate the signal-enhancing characteristics of monomer-coated very small superparamagnetic iron oxide (SPIO) particles used as a blood pool contrast medium for magnetic resonance (MR) angiography in the coronary arteries.
The particles used in this study were coated with citrate as the monomer (VSOP-C91). The particles have a total diameter of 7 nm and show the following relaxivities at 0.47 T: T1, 19 L/mmol. sec(-1); T2, 29 L/mmol. sec(-1). Fifteen cardiac MR examinations were performed at 1.5 T in five pigs. Images were acquired from immediately to 35 minutes (equilibrium phase) after intravenous injection of gadopentetate dimeglumine, gadobenate dimeglumine, and the very small SPIO particles (n = 5 for each substance).
Immediately after administration of gadopentetate dimeglumine, gadobenate dimeglumine, and the very small SPIO particles, respectively, increases in the signal-to-noise ratio in blood were 94%, 103%, and 102% and in myocardium were 83%, 83%, and 29% (P <.05, very small SPIO particles versus the low-molecular-weight gadolinium-based compounds). Differences in the blood-to-myocardium contrast-to-noise ratio and visualization of the coronary arteries and their branches were also significant.
VSOP-C91 significantly improves visualization of the coronary arteries at MR angiography from immediately to 35 minutes after injection.