In laparoscopic extraperitoneal herniorrhaphy, there have been no static calculations for nonfixed prostheses with regard to the ideal size of the prosthesis, mesh overlap on the hernial orifice, friction coefficient, and shear forces. The aim of the present study was to perform these static analyses. The friction coefficient of a polypropylene mesh was measured in an experimental setting. Based on the distribution of adhesive force and load on the mesh, we calculated the required mesh overlap over the hernial opening. The friction coefficient was determined as mu0 = 0.3. The friction surface required to immobilize the prosthesis is 4.16 times the stress surface. Assuming a safety factor of 2.5, the minimum distance between the margin of the prosthesis and that of the hernial opening should be equal to the diameter of the hernial opening. For smaller lesions we recommend a minimum mesh overlap of 2 cm over the hernial orifice. From a hernia size 2 cm and larger, the distance between the margin of the prosthesis and the hernial opening should be equal to the diameter of the orifice. From 4 cm and larger, the prosthesis should be secured with a stapler (or a similar mode of fixation) to prevent recurrence.
在腹腔镜腹膜外疝修补术中,对于非固定补片,尚未针对补片的理想尺寸、疝孔处补片重叠、摩擦系数和剪切力进行静态计算。本研究的目的是进行这些静态分析。在实验环境中测量了聚丙烯补片的摩擦系数。根据补片上粘合力和负荷的分布,我们计算了疝孔上方所需的补片重叠量。确定摩擦系数为μ0 = 0.3。固定补片所需的摩擦面是应力面的4.16倍。假设安全系数为2.5,补片边缘与疝孔边缘之间的最小距离应等于疝孔直径。对于较小的病变,我们建议在疝孔上方补片的最小重叠量为2 cm。对于疝大小为2 cm及以上的情况,补片边缘与疝孔之间的距离应等于疝孔直径。对于4 cm及以上的情况,应使用吻合器(或类似的固定方式)固定补片以防止复发。