To probe into the effectiveness and safety of clear lens extraction with phacoemulsification and implantation of posterior chamber intraocular lens (PC-IOL) to correct high myopia.
Phacoemulsification and implantation of PC-IOL through scleral tunnel incision was performed on 36 eyes of 26 high myopic patients with clear crystalline lens. The average age of patients was 53.9 years (36-67 years) old. The preoperative corrected visual acuity was 0.2-1.0. The mean preoperative spherical equivalent and astigmatism was (-13.11 +/- 4.33) D and (0.72 +/- 0.91) D respectively. The mean axial length was (28.02 +/- 2.14) mm. The mean diopter of IOL was (+8.62 +/- 4.76) D.
The uncorrected visual acuity improved in all cases postoperatively, with 25 eyes (69.4%) achieving > or = 0.5. After surgery, the corrected visual acuity improved in 27 eyes (75.0%), and was > or = 0.5 in 35 eyes (97.2%). The mean postoperative spherical equivalent and astigmatism was (-1.51 +/- 0.60) D and (0.64 +/- 0.80) D respectively. The average follow-up was 23.5 months (7-35 months). The postoperative complication was posterior capsular opacification (5.6%). No retinal hole or detachment and cystoid macular edema were observed in this series.
Clear lens phacoemulsification and PC-IOL implantation to correct high myopia is a safe, effective procedure serving as a refractive surgery. It is worth to spread due to good outcome of visual acuity, low incidence of complications, high predictability and stability.
探讨透明晶状体超声乳化吸出联合后房型人工晶状体(PC-IOL)植入术矫正高度近视的有效性和安全性。
对26例高度近视患者的36只透明晶状体眼行巩膜隧道切口超声乳化吸出联合PC-IOL植入术。患者平均年龄53.9岁(36 - 67岁)。术前矫正视力为0.2 - 1.0。术前平均球镜度数和散光分别为(-13.11±4.33)D和(0.72±0.91)D。平均眼轴长度为(28.02±2.14)mm。人工晶状体平均度数为(+8.62±4.76)D。
所有病例术后裸眼视力均有提高,25只眼(69.4%)达到≥0.5。术后27只眼(75.0%)矫正视力提高,35只眼(97.2%)≥0.5。术后平均球镜度数和散光分别为(-1.51±0.60)D和(0.64±0.80)D。平均随访23.5个月(7 - 35个月)。术后并发症为后囊膜混浊(5.6%)。本研究系列未观察到视网膜裂孔或脱离以及黄斑囊样水肿。
透明晶状体超声乳化吸出联合PC-IOL植入术矫正高度近视是一种安全、有效的屈光手术。因其视力预后良好、并发症发生率低、预测性和稳定性高,值得推广。