用于种植体模型的3种概念上不同的代型系统的准确性。

Accuracy of 3 conceptually different die systems used for implant casts.

作者信息

Wee Alvin G, Cheng Ansgar C, Eskridge Ryan N

机构信息

Section of Restorative Dentistry, Prosthodontics and Endodontics, College of Dentistry, The Ohio State University, Columbus, Ohio, 43210-9422, USA.

出版信息

J Prosthet Dent. 2002 Jan;87(1):23-9. doi: 10.1067/mpr.2002.121110.

Abstract

STATEMENT OF PROBLEM

Given that meticulous implant prosthodontic procedures are recommended to obtain the best possible intraoral fit, the die systems used for multi-implant casts warrant further investigation. PURPOSE. The purpose of this in vitro study was to compare the accuracy of implant casts fabricated from 3 conceptually different die systems at the solid, sectioned, and repeated stages.

MATERIAL AND METHODS

Thirty direct transfer implant impressions were made of the master cast with a polyether impression material. Ten experimental implant casts were fabricated for each of the 3 different die systems tested: double-pour (Pindex), plastic base (DVA), and die tray (KO Tray). The solid experimental casts were sectioned and then removed from the die system 30 times. Linear distances between steel balls placed on each abutment replica were measured with a traveling microscope to determine the accuracy of the experimental casts at different stages. Data were analyzed with repeated-measures analysis of variance (alpha=.05) and the post hoc Ryan-Einot-Gabriel-Welsch multiple-range test (REGWQ).

RESULTS

Repeated-measures analysis of variance revealed a significant interaction between the die systems and different stages (P=.0432). REGWQ showed the die tray system to be significantly more accurate at the solid than at the sectioned and repeated stages. The die tray system was significantly less accurate than the double-pour and plastic base systems at the sectioned stage.

CONCLUSION

Within the limitations of this study, the use of a double-pour or plastic base die system is recommended when sectioned dies are needed for a multi-implant-retained prosthesis.

摘要

问题陈述

鉴于推荐采用精细的种植义齿修复程序以获得尽可能好的口腔内贴合度,用于多颗种植体模型的代型系统值得进一步研究。目的:本体外研究的目的是比较在实体、切割和重复阶段由3种概念上不同的代型系统制作的种植体模型的准确性。

材料与方法

用聚醚印模材料对主模型制作30个直接转移种植体印模。对所测试的3种不同代型系统中的每一种制作10个实验性种植体模型:双层灌注(Pindex)、塑料基底(DVA)和代型托盘(KO Tray)。将实体实验模型切割,然后从代型系统中取出30次。用移动显微镜测量放置在每个基台复制体上的钢球之间的线性距离,以确定不同阶段实验模型的准确性。数据采用重复测量方差分析(α = 0.05)和事后Ryan-Einot-Gabriel-Welsch多重极差检验(REGWQ)进行分析。

结果

重复测量方差分析显示代型系统与不同阶段之间存在显著交互作用(P = 0.0432)。REGWQ显示代型托盘系统在实体阶段比在切割和重复阶段显著更准确。在切割阶段,代型托盘系统的准确性显著低于双层灌注和塑料基底系统。

结论

在本研究的局限性范围内,当多颗种植体支持的修复体需要切割代型时,建议使用双层灌注或塑料基底代型系统。