Suppr超能文献

多内部连接种植体修复体印模技术的评估

An evaluation of impression techniques for multiple internal connection implant prostheses.

作者信息

Vigolo Paolo, Fonzi Fulvio, Majzoub Zeina, Cordioli Giampiero

机构信息

Instiotute of Clinical Dentistry, University of Padua, Padua, Italy.

出版信息

J Prosthet Dent. 2004 Nov;92(5):470-6. doi: 10.1016/j.prosdent.2004.08.015.

Abstract

STATEMENT OF PROBLEM

Movement of impression copings inside the impression material using an open-tray impression technique during clinical and laboratory phases may cause inaccuracy in transferring the 3-dimensional spatial orientation of implants intraorally to the definitive cast. Consequently the restoration may require corrective procedures.

PURPOSE

This in vitro study evaluated the accuracy of 3 different impression techniques using polyether impression material to obtain a precise definitive cast for a multi-unit implant restoration with multiple internal connection implants.

MATERIAL AND METHODS

A reference acrylic resin model with 4 internal connection implants (3i Implant Innovations) was fabricated. Forty-five medium-consistency polyether impressions (Impregum Penta) of this model were made with square impression copings using an open-tray technique. Three groups of 15 specimens each were made with different impression techniques: in the first group, nonmodified square impression copings were used (NM group); in the second group, square impression copings were used and joined together with autopolymerizing acrylic resin before the impression procedure (R [resin] group); and in the third group, square impression copings previously airborne-particle abraded and coated with the manufacturer-recommended impression adhesive were used (M [modified] group). Matching implant replicas were screwed into the square impression copings in the impressions. Impressions were poured with ADA type IV stone (New Fujirock). A single calibrated examiner blinded to the nature of the impression technique used examined all definitive casts to evaluate the positional accuracy (mum) of the implant replica heads using a profile projector (at original magnification x10). These measurements were compared to the measurements calculated on the reference resin model which served as control. Data were analyzed with a 1-way analysis of variance at alpha=.05, followed by the Student Newman-Keuls test (alpha=.05).

RESULTS

The data obtained with the profile projector revealed significant differences within the 3 impression techniques ( P <.001). The Student Newman-Keuls procedure disclosed significant differences between the groups, with group R casts being significantly more accurate than group NM and group M casts ( P =.05). The mean distance (+/-SD) between the posterior implants compared to the reference acrylic resin model was 18.17 mum (+/- 6.4) greater for group R casts, 41.27 mum (+/- 8.4) greater for group M casts, and 46.21 mum (+/- 8.9) greater for group NM casts. Distances between the anterior implants were also greater than those recorded on the reference model. The distance was 15.23 mum (+/- 5.9) greater on group R casts, 38.17 mum (+/- 8.3) greater on group M casts, and 43.23 mum (+/- 8.7) greater on group NM casts.

CONCLUSION

Within the limitations of this study, improved accuracy of the definitive cast was achieved when the square impression copings joined together with autopolymerizing acrylic resin were used to make an impression of multiple internal connection implants.

摘要

问题陈述

在临床和实验室阶段,采用开放式托盘印模技术时,印模帽在印模材料内移动可能会导致将种植体的三维空间方向从口腔内不准确地转移到最终模型上。因此,修复体可能需要进行矫正程序。

目的

本体外研究评估了三种不同印模技术使用聚醚印模材料为具有多个内部连接种植体的多单位种植修复体获取精确最终模型的准确性。

材料与方法

制作了一个带有4个内部连接种植体(3i种植体创新公司)的参考丙烯酸树脂模型。使用开放式托盘技术,用方形印模帽对该模型制作了45个中等稠度的聚醚印模(Impregum Penta)。将每组15个标本分为三组,采用不同的印模技术:第一组,使用未改良的方形印模帽(NM组);第二组,使用方形印模帽并在印模程序前用自凝丙烯酸树脂连接在一起(R[树脂]组);第三组,使用预先进行空气颗粒研磨并涂有制造商推荐印模粘合剂的方形印模帽(M[改良]组)。将匹配的种植体复制件拧入印模中的方形印模帽中。用ADA IV型石膏(New Fujirock)灌注印模。由一名对所使用印模技术的性质不知情的单一校准检查者,使用轮廓投影仪(原始放大倍数为x10)检查所有最终模型,以评估种植体复制件头部的位置准确性(μm)。将这些测量结果与作为对照的参考树脂模型上计算出的测量结果进行比较。数据采用α = 0.05的单因素方差分析进行分析,随后进行Student Newman - Keuls检验(α = 0.05)。

结果

用轮廓投影仪获得的数据显示,三种印模技术之间存在显著差异(P < 0.001)。Student Newman - Keuls程序揭示了各组之间的显著差异,R组模型比NM组和M组模型显著更准确(P = 0.05)。与参考丙烯酸树脂模型相比,R组模型中后部种植体之间的平均距离(±标准差)大18.17μm(±6.4),M组模型大41.27μm(±8.4),NM组模型大46.21μm(±8.9)。前部种植体之间的距离也大于参考模型上记录的距离。R组模型上大15.23μm(±5.9),M组模型上大38.17μm(±8.3),NM组模型上大43.2μm(±8.7)。

结论

在本研究的局限性内,当使用与自凝丙烯酸树脂连接在一起的方形印模帽为多个内部连接种植体制作印模时,最终模型的准确性得到了提高。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验