Afonso K, Friede G L, Blau F M, Bandow G T, Rowe G G
J Appl Physiol. 1975 Nov;39(5):860-2. doi: 10.1152/jappl.1975.39.5.860.
A technique for measurement of retrograde coronary blood flow in intact anesthetized dogs is described. Occlusion of the coronary artery is produced by the inflation of a small rubber balloon at the tip of a no. 9 cardiac catheter placed under fluorescopy in a branch of the left coronary artery. Blood which bleeds back from the occluded coronary artery through the no. 9 catheter is diverted into a small reservoir of 1-ml capacity. The time to fill this reservoir is recorded electrically. Retrograde coronary blood flow is calculated from the time required to fill this reservoir. Results indicate good repeatability of meadurements. The technique seems to be a simple, adequate, and convenient means for assessing agents for possible vasodilator action on the collateral circulation in intact animals.
描述了一种用于测量完整麻醉犬逆行冠状动脉血流的技术。通过在荧光透视下将9号心导管尖端的小橡皮球囊充气,使其置于左冠状动脉分支中来造成冠状动脉闭塞。从闭塞的冠状动脉通过9号导管回流的血液被引流到一个容量为1毫升的小储液器中。用电记录充满这个储液器的时间。根据充满该储液器所需的时间计算逆行冠状动脉血流。结果表明测量具有良好的重复性。该技术似乎是一种简单、充分且方便的方法,用于评估对完整动物侧支循环可能具有血管舒张作用的药物。