A technique for measurement of retrograde coronary blood flow in intact anesthetized dogs.

作者信息

Afonso K, Friede G L, Blau F M, Bandow G T, Rowe G G

出版信息

J Appl Physiol. 1975 Nov;39(5):860-2. doi: 10.1152/jappl.1975.39.5.860.

Abstract

A technique for measurement of retrograde coronary blood flow in intact anesthetized dogs is described. Occlusion of the coronary artery is produced by the inflation of a small rubber balloon at the tip of a no. 9 cardiac catheter placed under fluorescopy in a branch of the left coronary artery. Blood which bleeds back from the occluded coronary artery through the no. 9 catheter is diverted into a small reservoir of 1-ml capacity. The time to fill this reservoir is recorded electrically. Retrograde coronary blood flow is calculated from the time required to fill this reservoir. Results indicate good repeatability of meadurements. The technique seems to be a simple, adequate, and convenient means for assessing agents for possible vasodilator action on the collateral circulation in intact animals.