Suppr超能文献

校正转诊偏倚对单光子发射计算机断层扫描诊断冠状动脉疾病的敏感性和特异性的影响。

Effects of adjustment for referral bias on the sensitivity and specificity of single photon emission computed tomography for the diagnosis of coronary artery disease.

作者信息

Miller Todd D, Hodge David O, Christian Timothy F, Milavetz James J, Bailey Kent R, Gibbons Raymond J

机构信息

Department of Internal Medicine, Mayo Clinic, Rochester, Minnesota 55905, USA.

出版信息

Am J Med. 2002 Mar;112(4):290-7. doi: 10.1016/s0002-9343(01)01111-1.

Abstract

PURPOSE

Referral bias, in which the result of a diagnostic test affects the subsequent referral for a more definitive test, influences the accuracy of noninvasive tests for coronary artery disease. This study evaluates the effect of referral bias on the apparent accuracy of single photon emission computed tomography (SPECT).

METHODS

Over a 10-year period, 14,273 patients without known coronary artery disease underwent stress SPECT. Coronary angiography was performed within 3 months after the stress test in 1853 patients (13%). The apparent sensitivity, specificity, and likelihood ratios of SPECT were determined in these patients, and then adjusted for referral bias using two different formulas.

RESULTS

The overwhelming majority (95%) of patients who underwent angiography had abnormal SPECT images. Apparent values for test indices were a sensitivity of 98%, a specificity of 13%, a likelihood ratio for a positive test of 1.1, and a likelihood ratio for a negative test of 0.15. Test indices adjusted for referral bias (using the two methods) were a sensitivity of 65% or 67%, a specificity of 67% or 75%, a likelihood ratio for a positive test of 2.0 or 2.7, and a likelihood ratio for a negative test of 0.44 or 0.52.

CONCLUSION

Referral bias has a marked effect on the apparent accuracy of stress SPECT for the diagnosis of coronary disease. Adjustment for referral bias yields estimates for sensitivity and specificity and likelihood ratios that better reflect the accuracy of the technique.

摘要

目的

诊断试验结果会影响后续进行更确定性检查的转诊,这种转诊偏倚会影响冠心病无创检查的准确性。本研究评估转诊偏倚对单光子发射计算机断层扫描(SPECT)表观准确性的影响。

方法

在10年期间,14273例无已知冠心病的患者接受了负荷SPECT检查。1853例患者(13%)在负荷试验后3个月内进行了冠状动脉造影。在这些患者中确定SPECT的表观敏感性、特异性和似然比,然后使用两种不同公式对转诊偏倚进行校正。

结果

接受血管造影的绝大多数患者(95%)SPECT图像异常。试验指标的表观值为敏感性98%、特异性13%、阳性试验似然比1.1、阴性试验似然比0.15。校正转诊偏倚后的试验指标(使用两种方法)为敏感性65%或67%、特异性67%或75%、阳性试验似然比2.0或2.7、阴性试验似然比0.44或0.52。

结论

转诊偏倚对负荷SPECT诊断冠心病的表观准确性有显著影响。校正转诊偏倚后得出的敏感性、特异性和似然比估计值能更好地反映该技术的准确性。