Suppr超能文献

基因对大鼠声学惊吓刺激心血管反应的影响。

Genetic influences on cardiovascular responses to an acoustic startle stimulus in rats.

作者信息

Baudrie V, Laude D, Chaouloff F, Elghozi J L

机构信息

INSERM E0107, Centre de Pharmacologie Clinique de l'Association Claude Bernard, Hôpital Necker, Paris, France.

出版信息

Clin Exp Pharmacol Physiol. 2001 Dec;28(12):1096-9. doi: 10.1046/j.1440-1681.2001.03593.x.

Abstract
  1. The aim of the present study was to assess the cardiovascular differences among five inbred rat strains (n=16 per strain), including spontaneously hypertensive rats (SHR), Wistar Kyoto (WKY) rats, Wistar Furth (WF) rats, Fischer (F344) rats and Lewis (Lew) rats and the usual outbred Wistar (W) rat strain (n=25). 2. These strains were compared under resting conditions for blood pressure (BP) and heart rate (HR) levels and for their baroreceptor-HR reflex sensitivity. In addition, their responses to an acoustic startle stimulus were measured. 3. A consistent rise in BP was observed among the groups as a result of the noise stimulus. This rise in systolic BP (SBP) averaged (+/-SEM) 37 +/- 2 mmHg in the SHR and 34 +/- 4 mmHg in F344 rats, while the response was only 23 +/- 3 mmHg in WKY rats. Pulse pressure (PP) was increased following noise in all groups. The delay for the BP response for all groups combined was 1.6 +/- 0.1 s. 4. Most animals had minimal HR variations, except F344 rats, responding with a 42 +/- 13 b.p.m. decrease 3.0 s after the stimulus (i.e. 1.3 s after the maximal 34 +/- 4 mmHg SBP rise). 5. The highest SBP (160 +/- 3 mmHg) and diastolic BP (104 +/- 3 mmHg) were observed in inbred SHR. Other groups were normotensive. Resting PP was elevated for SHR (56 +/- 2 mmHg) compared with the other groups (40 +/- 2 mmHg). The highest HR was found in F344 and WF rats, with 389 +/- 11 and 372 +/- 7 b.p.m., respectively. The lowest HR was observed in SHR and Lewis rats, with 335 +/- 7 and 323 +/- 7 b.p.m., respectively. The least sensitive baroreflex function was observed in SHR (0.8 +/- 0.1 b.p.m./mmHg) compared with the other strains (1.4 +/- 0.2 b.p.m./mmHg). 6. The present study confirms the importance of genetic factors on the cardiovascular responses of rats to a noise startle stimulus. Two inbred normotensive rat strains, namely F344 and WKY rats, which exhibit a substantial difference in pressor response to noise, may be used to unravel the mechanisms of sympathetic activation.
摘要
  1. 本研究的目的是评估五种近交系大鼠(每个品系n = 16)的心血管差异,包括自发性高血压大鼠(SHR)、Wistar Kyoto(WKY)大鼠、Wistar Furth(WF)大鼠、Fischer(F344)大鼠和Lewis(Lew)大鼠,以及普通远交Wistar(W)大鼠品系(n = 25)。2. 在静息条件下比较这些品系的血压(BP)和心率(HR)水平及其压力感受器 - HR反射敏感性。此外,还测量了它们对听觉惊吓刺激的反应。3. 由于噪声刺激,各实验组的血压均持续升高。收缩压(SBP)升高幅度在SHR组平均为(±标准误)37±2 mmHg,F344大鼠组为34±4 mmHg,而WKY大鼠组的反应仅为23±3 mmHg。所有组的脉压(PP)在噪声刺激后均升高。所有组血压反应的延迟时间为1.6±0.1 s。4. 除F344大鼠外,大多数动物的心率变化极小,F344大鼠在刺激后3.0 s(即收缩压最大升高34±4 mmHg后1.3 s)心率下降42±13次/分钟。5. 在近交SHR大鼠中观察到最高收缩压(160±3 mmHg)和舒张压(104±3 mmHg)。其他组血压正常。与其他组(40±2 mmHg)相比,SHR大鼠静息脉压升高(56±2 mmHg)。F344大鼠和WF大鼠心率最高,分别为389±11次/分钟和372±7次/分钟。SHR大鼠和Lewis大鼠心率最低,分别为335±7次/分钟和323±7次/分钟。与其他品系(1.4±0.2次/分钟/mmHg)相比,SHR大鼠的压力反射功能最不敏感(0.8±0.1次/分钟/mmHg)。6. 本研究证实了遗传因素对大鼠心血管系统对噪声惊吓刺激反应的重要性。两种近交正常血压大鼠品系,即F344大鼠和WKY大鼠,对噪声的升压反应存在显著差异,可用于揭示交感神经激活的机制。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验