Suppr超能文献

新生儿实验室采血:动脉导管采血结果与自动毛细血管采血装置采血结果的比较。

Neonatal laboratory blood sampling: comparison of results from arterial catheters with those from an automated capillary device.

作者信息

Johnson K J, Cress G A, Connolly N W, Burmeister L F, Widness J A

机构信息

University of Iowa Hospitals and Clinics, Department of Pediatrics, W226 GH 200 Hawkins Drive, Iowa City, IA 52242, USA.

出版信息

Neonatal Netw. 2000 Feb;19(1):27-34. doi: 10.1891/0730-0832.19.1.27.

Abstract

PURPOSE

To compare neonatal laboratory results from capillary blood samples drawn using the Tenderfoot automated capillary sampling device with those drawn through arterial catheters.

DESIGN

Prospective, paired comparisons of laboratory results from capillary and arterial blood.

SAMPLE

Twenty-one infants being cared for in an NICU and having indwelling arterial catheters through which a variety of predominantly glucose-containing fluids were being administered.

MAIN OUTCOME VARIABLES

Statistical comparisons of paired capillary and arterial results of pH, PO2, PCO2, lactate, sodium, potassium, ionized calcium, and hematocrit.

RESULTS

No capillary-arterial differences were observed for pH, PCO2, lactate, or sodium. Although capillary results were slightly, but significantly (p < .01), higher for potassium (+0.4 mEq/liter), ionized calcium (+0.47 mg/dl), and hematocrit (+4 percent), these differences fell within acceptable Clinical Laboratories Improvement Act (CLIA) performance criteria. Markedly lower PO2 (-30.2 mmHg) and glucose (-61 mg/dl) values were observed with capillary sampling. With the exception of results for PaO2 and plasma glucose, capillary blood drawn using the Tenderfoot automated device yields laboratory results comparable to those from blood drawn from arterial catheters as assessed by CLIA performance criteria.

摘要

目的

比较使用Tenderfoot自动毛细血管采样设备采集的新生儿毛细血管血样本与通过动脉导管采集的血样的实验室检测结果。

设计

对毛细血管血和动脉血的实验室检测结果进行前瞻性配对比较。

样本

21名在新生儿重症监护病房接受护理且留置动脉导管的婴儿,通过动脉导管输注多种主要含葡萄糖的液体。

主要观察变量

pH值、PO2、PCO2、乳酸、钠、钾、离子钙和血细胞比容的毛细血管血与动脉血配对结果的统计学比较。

结果

pH值、PCO2、乳酸或钠在毛细血管血与动脉血之间未观察到差异。尽管毛细血管血的钾(+0.4毫当量/升)、离子钙(+0.47毫克/分升)和血细胞比容(+4%)结果略高,但差异显著(p <.01),不过这些差异仍在可接受的《临床实验室改进法案》(CLIA)性能标准范围内。毛细血管采样时观察到PO2(-30.2 mmHg)和葡萄糖(-61毫克/分升)值明显较低。根据CLIA性能标准评估,除PaO2和血浆葡萄糖结果外,使用Tenderfoot自动设备采集的毛细血管血产生的实验室检测结果与从动脉导管采集的血样相当。