Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging.

作者信息

Zaidi H, Diaz-Gomez M, Boudraa A, Slosman D O

机构信息

Division of Nuclear Medicine, Geneva University Hospital, Switzerland.

出版信息

Phys Med Biol. 2002 Apr 7;47(7):1143-60. doi: 10.1088/0031-9155/47/7/310.

Abstract

Segmented attenuation correction is now a widely accepted technique to reduce noise propagation from transmission scanning in positron emission tomography (PET). In this paper, we present a new method for segmenting transmission images in whole-body scanning. This reduces the noise in the correction maps while still correcting for differing attenuation coefficients of specific tissues. Based on the fuzzy C-means (FCM) algorithm, the method segments the PET transmission images into a given number of clusters to extract specific areas of differing attenuation such as air, the lungs and soft tissue, preceded by a median filtering procedure. The reconstructed transmission image voxels are, therefore, segmented into populations of uniform attenuation based on knowledge of the human anatomy. The clustering procedure starts with an overspecified number of clusters followed by a merging process to group clusters with similar properties (redundant clusters) and removal of some undesired substructures using anatomical knowledge. The method is unsupervised, adaptive and allows the classification of both pre- or post-injection transmission images obtained using either coincident 68Ge or single-photon 137Cs sources into main tissue components in terms of attenuation coefficients. A high-quality transmission image of the scanner bed is obtained from a high statistics scan and added to the transmission image. The segmented transmission images are then forward projected to generate attenuation correction factors to be used for the reconstruction of the corresponding emission scan. The technique has been tested on a chest phantom simulating the lungs, heart cavity and the spine, the Rando-Alderson phantom, and whole-body clinical PET studies showing a remarkable improvement in image quality, a clear reduction of noise propagation from transmission into emission data allowing for reduction of transmission scan duration. There was very good correlation (R2 = 0.96) between maximum standardized uptake values (SUVs) in lung nodules measured on images reconstructed with measured and segmented attenuation correction with a statistically significant decrease in SUV (17.03% +/- 8.4%, P < 0.01) on the latter images, whereas no proof of statistically significant differences on the average SUVs was observed. Finally, the potential of the FCM algorithm as a segmentation method and its limitations as well as other prospective applications of the technique are discussed.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验