Williams H D W, Browne G, Gie G A, Ling R S M, Timperley A J, Wendover N A
Princess Elizabeth Orthopaedic Centre, Exeter, England, UK.
J Bone Joint Surg Br. 2002 Apr;84(3):324-34. doi: 10.1302/0301-620x.84b3.12261.
We describe our experience with the implantation of 325 Exeter Universal hips. The fate of every implant was known. The procedures were undertaken by surgeons of widely differing experience. At follow-up at 12 years, survivorship with revision of the femoral component for aseptic loosening as the endpoint was 100% (95% CI 98 to 100). Survivorship with revision of the acetabular component for aseptic loosening as the endpoint was 96.86% (95% CI 93.1 to 98.9) and that with any reoperation as the endpoint 91.74% (95% CI 87.7 to 95.8). No adverse features have emerged as a consequence of the modular connection between the head and neck of the implant.
我们描述了325例Exeter通用髋关节植入的经验。每例植入物的情况均已知晓。手术由经验差异很大的外科医生进行。在12年的随访中,以无菌性松动翻修股骨部件为终点的生存率为100%(95%可信区间98%至100%)。以无菌性松动翻修髋臼部件为终点的生存率为96.86%(95%可信区间93.1%至98.9%),以任何再次手术为终点的生存率为91.74%(95%可信区间87.7%至95.8%)。植入物头颈之间的模块化连接未产生任何不良特征。