Suppr超能文献

埃克塞特通用骨水泥型股骨假体8至12年随访。对首批325例髋关节的研究。

The Exeter universal cemented femoral component at 8 to 12 years. A study of the first 325 hips.

作者信息

Williams H D W, Browne G, Gie G A, Ling R S M, Timperley A J, Wendover N A

机构信息

Princess Elizabeth Orthopaedic Centre, Exeter, England, UK.

出版信息

J Bone Joint Surg Br. 2002 Apr;84(3):324-34. doi: 10.1302/0301-620x.84b3.12261.

Abstract

We describe our experience with the implantation of 325 Exeter Universal hips. The fate of every implant was known. The procedures were undertaken by surgeons of widely differing experience. At follow-up at 12 years, survivorship with revision of the femoral component for aseptic loosening as the endpoint was 100% (95% CI 98 to 100). Survivorship with revision of the acetabular component for aseptic loosening as the endpoint was 96.86% (95% CI 93.1 to 98.9) and that with any reoperation as the endpoint 91.74% (95% CI 87.7 to 95.8). No adverse features have emerged as a consequence of the modular connection between the head and neck of the implant.

摘要

我们描述了325例Exeter通用髋关节植入的经验。每例植入物的情况均已知晓。手术由经验差异很大的外科医生进行。在12年的随访中,以无菌性松动翻修股骨部件为终点的生存率为100%(95%可信区间98%至100%)。以无菌性松动翻修髋臼部件为终点的生存率为96.86%(95%可信区间93.1%至98.9%),以任何再次手术为终点的生存率为91.74%(95%可信区间87.7%至95.8%)。植入物头颈之间的模块化连接未产生任何不良特征。