Menicucci Giulio, Mossolov Alexei, Mozzati Marco, Lorenzetti Massimo, Preti Giulio
Prosthodontic Department, School of Dentistry, University of Turin, Turin, Italy.
Clin Oral Implants Res. 2002 Jun;13(3):334-41. doi: 10.1034/j.1600-0501.2002.130315.x.
This study investigated, with the use of two- and three-dimensional finite element analysis, the peri-implant stress that occurred during loading of a tooth that was rigidly connected to a distally placed implant. A fixed bond between the bone and the implant was assumed, while the periodontal ligament was represented by means of three-dimensional nonlinear visco-elastic spring elements. Two different loading conditions were compared in the study: i) an axially directed static load of 50 kg that was applied to the tooth for 10 s, and ii) a transitional load of 50 kg that was applied for 5 milliseconds. Load duration appeared to have a greater influence than load intensity on the stress distribution in the bone around an implant and a rigidly connected tooth. Static load is, therefore, potentially more harmful for peri-implant bone than transitional load. The periodontal ligament seems to play a key role in the stress distribution between a tooth and a rigidly connected implant.
本研究采用二维和三维有限元分析方法,对刚性连接至远中种植体的牙齿加载过程中发生的种植体周围应力进行了研究。假定骨与种植体之间存在固定连接,而牙周膜则通过三维非线性粘弹性弹簧单元来表示。本研究比较了两种不同的加载条件:i)对牙齿施加50 kg的轴向静态载荷,持续10秒;ii)施加50 kg的过渡载荷,持续5毫秒。加载持续时间对种植体周围骨组织及刚性连接牙齿的应力分布影响似乎比加载强度更大。因此,静态载荷对种植体周围骨组织的潜在危害可能比过渡载荷更大。牙周膜似乎在牙齿与刚性连接种植体之间的应力分布中起关键作用。