Peri-implant bone tissue strains in cases of dehiscence: a finite element study.

作者信息

Van Oosterwyck Hans, Duyck Joke, Vander Sloten Jos, Van Der Perre Georges, Naert Ignace

机构信息

Division of Biomechanics and Engineering Design, KU Leuven, Leuven, Belgium.

出版信息

Clin Oral Implants Res. 2002 Jun;13(3):327-33. doi: 10.1034/j.1600-0501.2002.130314.x.

Abstract

When patients with a narrow alveolar bone ridge are treated with oral implants, a dehiscence can occur. The lack of bony support at the buccal or lingual side of the implant may present an unfavourable situation from a biomechanical point of view. The hypothesis as to whether the presence of dehiscence leads to an increased risk of marginal bone overload was tested by means of the finite element method. Three different situations for a cylindrical oral implant, which was placed in a mandible, were modelled: i) no dehiscence, ii) a dehiscence at the buccal side and iii) dehiscences at the buccal and lingual sides. It was found that the presence of buccal and/or lingual dehiscences led to a marked increase in marginal bone strains at the mesial and distal sides of the implant, thus increasing the risk of bone tissue overload at these locations. Marginal bone strains at the buccal and/or lingual sides, however, did not increase.