Suppr超能文献

带有分段式和非分段式基台的种植体-牙齿连接修复体的光弹性应力分析

Photoelastic stress analysis of implant-tooth connected prostheses with segmented and nonsegmented abutments.

作者信息

Ochiai Kent T, Ozawa Shogo, Caputo Angelo A, Nishimura Russell D

机构信息

Division of Advanced Prosthodontics, Biomaterials Science and Hospital Dentistry, UCLA School of Dentistry, Los Angeles, CA 90095, USA.

出版信息

J Prosthet Dent. 2003 May;89(5):495-502. doi: 10.1016/s0022-3913(03)00167-7.

Abstract

STATEMENT OF PROBLEM

There is some question about whether implant abutment selection affects the transfer of load between connected implants and natural teeth.

PURPOSE

The purpose of this study was to compare stress transfer patterns with either 1 or 2 posterior implants connected to a single anteriorly located simulated natural tooth with either 1 or 2 segmented and nonsegmented implant abutments under relevant functional loads by use of the photoelastic stress analysis technique.

MATERIAL AND METHODS

A model of a human left mandible, edentulous posterior to the first premolar, with two 3.75-mm x 13-mm screw-type implants embedded within the edentulous area, was fabricated from photoelastic materials. The implants were in the first and second molar positions. Two fixed partial denture prosthetic restorations were fabricated with either segmented conical abutments or nonsegmented UCLA abutments. Vertical occlusal loads were applied at fixed locations on the restorations. The photoelastic stress fringes that developed in the supporting mandible were monitored visually and recorded photographically. The stress intensity (number of fringes), stress concentrations (closeness of fringes), and their locations were subjectively compared.

RESULTS

Loading on the restoration over the simulated tooth generated apical stresses of similar intensity (fringe order) at the tooth and the first molar implant for both abutment types. Low-level stress was transferred to the second molar implant. Loading directed on the implant-supported region of the restoration demonstrated low transfer of stress to the simulated tooth. Nonvertical stress transfer with slightly higher intensity was observed for the nonsegmented abutment.

CONCLUSION

Within the limitations of this simulation study, stress distribution and intensity for the 2 implant conditions was similar for segmented and nonsegmented abutment designs. Magnitude of stresses observed for both abutment designs was similar for the single implant condition. Vertical loading produced more nonaxial stresses away from the force applied for the 1 implant condition with the nonsegmented abutment. Direct loading results were similar for both abutment designs. Specific recommendations for selection of implant abutment and application should be based on clinical criteria.

摘要

问题陈述

种植体基台的选择是否会影响相连种植体与天然牙之间的负荷传递存在一些疑问。

目的

本研究的目的是通过光弹性应力分析技术,比较在相关功能负荷下,1个或2个后牙种植体与单个位于前方的模拟天然牙相连,采用1个或2个分段式和非分段式种植体基台时的应力传递模式。

材料与方法

用光弹性材料制作一个人类左下颌骨模型,第一前磨牙后方无牙,在无牙区域植入两颗3.75毫米×13毫米的螺旋式种植体,种植体位于第一和第二磨牙位置。制作两个固定局部义齿修复体,分别采用分段式锥形基台或非分段式加州大学洛杉矶分校(UCLA)基台。在修复体的固定位置施加垂直咬合负荷。目视监测并摄影记录在下颌骨支持结构中产生的光弹性应力条纹。主观比较应力强度(条纹数量)、应力集中(条纹密集程度)及其位置。

结果

对于两种基台类型,在模拟牙上方的修复体上加载时,牙齿和第一磨牙种植体处产生的根尖应力强度(条纹级数)相似。低水平应力传递至第二磨牙种植体。在修复体的种植体支持区域加载时,显示应力向模拟牙的传递较低。对于非分段式基台,观察到强度稍高的非垂直应力传递。

结论

在本模拟研究的局限性内,分段式和非分段式基台设计在两种种植体情况下的应力分布和强度相似。在单个种植体情况下,两种基台设计观察到的应力大小相似。对于单个种植体情况,在采用非分段式基台时,垂直加载产生的非轴向应力更多地远离施力方向。两种基台设计的直接加载结果相似。种植体基台选择和应用的具体建议应基于临床标准。