In vivo behaviour of hydroxyapatite coatings on titanium implants: a quantitative study in the rabbit.

作者信息

Darimont G L, Cloots R, Heinen E, Seidel L, Legrand R

机构信息

Department of Oral Implantology and Periodontology, Institute of Dentistry, University of Liege, CHU, Belgium.

出版信息

Biomaterials. 2002 Jun;23(12):2569-75. doi: 10.1016/s0142-9612(01)00392-1.

Abstract

The aim of this study was to evaluate quantitatively the behaviour of in vivo hydroxyapatite coated implants (HA) in the rabbit over time, and to compare the results with observations made on titanium plasma spray implants (TPS). Results were analysed according to the percentage of bone contact. Eighteen HA cylindrical implants (3.25 x 8 mm) and 6 TPS cylindrical implants from Steri-Oss were placed in the epiphysis of the femur in 24 white rabbits. Each rabbit received one implant. Three rabbits with one HA implant (n = 3) and 1 rabbit with one TPS implant (n = 1) were sacrificed after implantation periods of 2, 4, 6, 8, 10 and 12 months. Implants were cut along the long axis and prepared for histological and histomorphometrical evaluations. Measurements of coating thickness and percentage of bone contact were performed with scanning electron microscopy analysis on the sides of the implant, in 3 different types of bone, namely cortical, trabecular and marrow. In cortical bone, dense bone was apposed to the HA implants: from 92.3 +/- 5.5% at 2 months to 89.6 +/- 6.5% at 1 year, with no significant regression of HA thickness (P = 0.37). TPS coating showed less bone contact, but thickness was stable (P = 0.46). In trabecular zone, where bone contact was less pronounced, a significant regression of HA coatings thickness (P < 0.05) was observed. Nevertheless TPS coatings were stable (P = 0.81). Histomorphometrical results demonstrated that a highly significant regression (P < 0.0001) of HA thickness was observed in the marrow area, where the bone-to-implant contact never exceeded 7.6% from 2 to 12 months. TPS coating did not reveal any sign of resorption (P = 0.88), despite a rare bone contact. Histological analysis revealed inflammatory and giant cells, principally in the marrow area in contact with HA coating, but always in restrictive numbers. We conclude that bone contact protected the HA coating from resorption.

摘要

本研究的目的是定量评估体内羟基磷灰石涂层植入物(HA)在兔体内随时间的行为,并将结果与钛等离子喷涂植入物(TPS)的观察结果进行比较。根据骨接触百分比分析结果。将18个HA圆柱形植入物(3.25×8mm)和6个来自Steri-Oss的TPS圆柱形植入物植入24只白兔的股骨骨骺中。每只兔子接受一个植入物。在植入2、4、6、8、10和12个月后,处死3只植入一个HA植入物的兔子(n = 3)和1只植入一个TPS植入物的兔子(n = 1)。将植入物沿长轴切开,准备进行组织学和组织形态计量学评估。通过扫描电子显微镜分析在植入物侧面的3种不同类型的骨(即皮质骨、小梁骨和骨髓)中测量涂层厚度和骨接触百分比。在皮质骨中,致密骨与HA植入物相邻:从2个月时的92.3±5.5%到1年时的89.6±6.5%,HA厚度无显著消退(P = 0.37)。TPS涂层显示骨接触较少,但厚度稳定(P = 0.46)。在小梁区域,骨接触不太明显,观察到HA涂层厚度有显著消退(P < 0.05)。然而,TPS涂层是稳定的(P = 0.81)。组织形态计量学结果表明,在骨髓区域观察到HA厚度有高度显著的消退(P < 0.0001),从2个月到12个月,骨与植入物的接触从未超过7.6%。尽管骨接触很少,但TPS涂层未显示任何吸收迹象(P = 0.88)。组织学分析显示有炎症细胞和巨细胞,主要在与HA涂层接触的骨髓区域,但数量总是有限的。我们得出结论,骨接触可保护HA涂层不被吸收。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验