As a result of the development of a new fixing mechanism, which permitted the test of peak value of tensile strength in Achilles tendons, the following facts were demonstrated: 1. The average value of static maximum of tensile strength is about 7, 5 kp/mm2, of the dynamic maximum is about 10, 1 kp/mm2. 2. The charge maximum decreases with progressive age. 3. The tensile strength depends on the minimal cross-section plane of the tendon. 4. The minimal cross section plane decreases with progressive age. 5. With the test of dynamic tensile strength it is possible to malinger a Achilles tendon rupture.
由于开发了一种新的固定机制,从而能够测试跟腱拉伸强度的峰值,结果表明了以下事实:1. 拉伸强度静态最大值的平均值约为7.5kp/mm²,动态最大值约为10.1kp/mm²。2. 负荷最大值随年龄增长而降低。3. 拉伸强度取决于肌腱的最小横截面。4. 最小横截面随年龄增长而减小。5. 通过动态拉伸强度测试,有可能伪装跟腱断裂。