Archer Stephen, Michelakis Evangelos
Department of Medicine (Cardiology) and the Vascular Biology Group, University of Alberta, Edmonton, Alberta T6G 2B7, Canada.
News Physiol Sci. 2002 Aug;17:131-7. doi: 10.1152/nips.01388.2002.
Hypoxic pulmonary vasoconstriction matches perfusion to ventilation and optimizes systemic oxygenation. Alterations in PO(2) are sensed by a vascular redox O(2) sensor in the pulmonary artery smooth muscle cell, probably within the mitochondria. This creates a signal that modulates redox-sensitive K(+) channels, thereby controlling membrane potential, Ca(2+) entry, and tone.
低氧性肺血管收缩使灌注与通气相匹配,并优化全身氧合。肺动脉平滑肌细胞中的血管氧化还原氧传感器(可能在线粒体内)可感知PO₂的变化。这会产生一个信号,调节对氧化还原敏感的钾通道,从而控制膜电位、钙离子内流和张力。