The objective of this study was to investigate the ability of a milk line sampling device to obtain a representative sample by comparing SCC and bacterial culture results between milk line and bulk tank samples for milk harvested from the same group of cows at the same milking. A total of 42 paired milk line and bulk tank samples were collected at separate milking events from 21 different herds. Concordance correlation coefficients showed a high level of agreement between the two sample types, with values ranging between 0.74 and 0.99 for all parameters and bacterial species measured. ANOVA showed that SCC and bacterial culture results for Streptococcus agalactiae, Staphylococcus aureus, Streptococcus non-agalactiae, Coliforms, and coagulase-negative staphylococci were neither numerically or statistically different between milk line and bulk tank samples. KAPPA analysis showed that overall agreement beyond chance between milk line and bulk tank samples in determining whether a herd was positive or negative for either Strep. agalactiae or Staph. aureus were 100 and 75%, respectively. While further research is needed to fully assess the utility of this tool for the purpose of bacterial culture, the results of this study suggest that the strategy of milk line sampling is a very promising monitoring tool. This sampling strategy should provide producers with inexpensive and timely information that will help to improve programs for monitoring milk quality and udder health in commercial dairy herds.

摘要

本研究的目的是通过比较同一组奶牛在同一挤奶时奶管线样本和奶罐样本之间的体细胞计数(SCC)及细菌培养结果,来调查奶管线采样设备获取代表性样本的能力。在21个不同牛群的不同挤奶过程中,共收集了42对奶管线和奶罐样本。一致性相关系数显示两种样本类型之间具有高度一致性,所有测量参数和细菌种类的值在0.74至0.99之间。方差分析表明,无乳链球菌、金黄色葡萄球菌、非无乳链球菌、大肠菌群和凝固酶阴性葡萄球菌的SCC及细菌培养结果在奶管线样本和奶罐样本之间在数值上或统计学上均无差异。KAPPA分析表明,在确定牛群无乳链球菌或金黄色葡萄球菌检测呈阳性或阴性时,奶管线样本和奶罐样本之间总体一致性超过随机概率,分别为100%和75%。虽然需要进一步研究以全面评估该工具用于细菌培养的效用,但本研究结果表明奶管线采样策略是一种非常有前景的监测工具。这种采样策略应为生产者提供廉价且及时的信息,有助于改进商业奶牛场的牛奶质量和乳房健康监测计划。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验