Eye (Lond). 2002 Sep;16(5):543-51. doi: 10.1038/sj.eye.6700119.

Abstract

PURPOSE

To evaluate the compression characteristics of the human lens nucleocortex in relation to its LOCSIII clinical grading.

METHODS

Sixteen subjects undergoing planned extracapsular cataract surgery had pre-operative slit-lamp examination and assessment of cataract LOCSIII grade followed by postoperative in vitro evaluation of the nucleus with measurement of 'linear compressibility' by a purpose-designed caliper incorporating a strain gauge, enabling the derivation of a graph of nuclear compression (D (mm) against applied force (F (N)).

RESULTS

Nuclear colour correlates with the force required to compress a lens to 75% of its original depth (F75) (R = 0.625, P = 0.017). Nuclear opalescence correlates with the force required to compress a lens to 75% of its original depth (R = 0.651, P = 0.012) and inversely with linear compressibility (DeltaD/DeltaF, the slope of the graph of nuclear compression against applied force) (R = -0.610, P = 0.014). F75 is a direct and linear compressibility is an inverse related parameter of lens nucleus 'hardness'.

CONCLUSION

A new instrument is described which allows measurement of 'hardness'-related compression characteristics of the human cataract in vitro. There is a relationship between the LOCSIII clinical classification of nuclear cataracts and mechanical compression characteristics of the cataractous lens. LOCSIII classification may aid the preoperative planning of an appropriate surgical approach to an individual cataract.

摘要

目的

评估人晶状体核皮质的压缩特性及其与LOCSIII临床分级的关系。

方法

16名计划接受白内障囊外摘除术的受试者在术前进行裂隙灯检查并评估白内障的LOCSIII分级,术后对晶状体核进行体外评估,使用一种专门设计的带有应变仪的卡尺测量“线性压缩性”,从而得出核压缩图(D(毫米)与施加力(F(牛顿)))。

结果

核颜色与将晶状体压缩至其原始深度的75%所需的力(F75)相关(R = 0.625,P = 0.017)。核混浊与将晶状体压缩至其原始深度的75%所需的力相关(R = 0.651,P = 0.012),与线性压缩性(ΔD/ΔF,核压缩图相对于施加力的斜率)呈负相关(R = -0.610,P = 0.014)。F75是晶状体核“硬度”的直接相关参数,而线性压缩性是其反向相关参数。

结论

描述了一种新仪器,可在体外测量人白内障与“硬度”相关的压缩特性。核性白内障的LOCSIII临床分类与白内障晶状体的机械压缩特性之间存在关联。LOCSIII分类可能有助于为个体白内障制定合适的手术方法的术前规划。