Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification.

作者信息

Módis László Jr, Szalai Eszter, Flaskó Zsuzsa, Németh Gábor

机构信息

Department of Ophthalmology, Clinical Center, University of Debrecen, Debrecen, Hungary.

出版信息

Rom J Ophthalmol. 2016 Apr-Jun;60(2):109-115.

Abstract

PURPOSE

To study the endothelial cell morphology and corneal thickness changes after phacoemulsification by using the OZil torsional and longitudinal ultrasound techniques (Infiniti Vision System, Alcon Laboratories).

SETTING

Department of Ophthalmology, Clinical Center, University of Debrecen, Debrecen, Hungary.

METHODS

52 patients with cataract were randomly assigned to longitudinal ultrasound and torsional mode group. All surgeries were performed through a 2.2 mm clear corneal incision, the method employed being divide and conquer. The endothelial morphometry such as cell density (ECD), mean cell area, coefficient of variation of cell area, and central corneal thickness were examined with specular microscopy (EM-1000, Tomey) preoperatively and 4, 8 weeks postoperatively.

RESULTS

ECD values decreased significantly in both surgical groups (P < .001, repeated- mesures ANOVA), the postoperative endothelial cell loss was higher in the longitudinal ultrasound mode group (3.5% and 6.5%, at 4 and 8 weeks after surgery) than in the torsional group (3.3% and 5.5%, at 4 and 8 weeks after surgery), the difference not being significant between the two groups (P = .164 and P = .479, at 4 and 8 weeks after surgery, Mann-Whitney test). There was no statistically significant difference in any of the assessed parameters between the two surgical groups (P > .05). No significant correlation was found between the endothelial cell loss and the nucleus density.

CONCLUSIONS

Both phacoemulsification techniques were safe and effective. The torsional handpiece performs oscillatory movements and delivers less energy into the eye than the longitudinal ultrasound technique, therefore providing more favorable energy and thermal safety profile.

摘要

目的

使用OZil扭转和纵向超声技术(爱尔康实验室的Infiniti Vision System)研究白内障超声乳化术后内皮细胞形态及角膜厚度变化。

设置

匈牙利德布勒森大学临床中心眼科。

方法

52例白内障患者随机分为纵向超声组和扭转模式组。所有手术均通过2.2mm透明角膜切口进行,采用分而治之法。术前及术后4周、8周用镜面显微镜(Tomey EM - 1000)检查内皮形态测量指标,如细胞密度(ECD)、平均细胞面积、细胞面积变异系数及中央角膜厚度。

结果

两组手术患者的ECD值均显著下降(P <.001,重复测量方差分析),纵向超声模式组术后内皮细胞丢失率(术后4周和8周分别为3.5%和6.5%)高于扭转组(术后4周和8周分别为3.3%和5.5%),但两组间差异无统计学意义(术后4周和8周时P分别为.164和.479,曼 - 惠特尼检验)。两组手术患者在任何评估参数上均无统计学显著差异(P >.05)。未发现内皮细胞丢失与核密度之间存在显著相关性。

结论

两种超声乳化技术均安全有效。扭转式手柄进行振荡运动,与纵向超声技术相比向眼内传递的能量更少,因此提供了更有利的能量和热安全性。

相似文献

本文引用的文献

3
Heat production: Longitudinal versus torsional phacoemulsification.产热:纵向与扭转式超声乳化术
J Cataract Refract Surg. 2009 Oct;35(10):1799-805. doi: 10.1016/j.jcrs.2009.04.046.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验