Scotti P, Aresini G
Poumon Coeur. 1975;31(5):309-12.
A study of the behaviour of global and partial lung ductances for CO having for aim to value the lung diffusion function in 97 silicotic workers was undertaken by authors. The workers were divided into three groups according to the Cincinnati classification. The mean values of the global ductance for CO let appear a fall in all the groups when comparison is made with the standard values previously registered in a group of normal subjects. The partial ductances have put in evidence a fall in the mean values below the normal values, only for what concerns the alveolar-capillar ductance for groups 2 and 3. The study of partial ductances in bronchitic and non-bronchitic silicotic subjects lets appear in the first ones a fall in the ventilatory and alveolar-capillar ductances,-- and in the second ones an isolated fall in the alveolar-capillar ductance.
作者对97名矽肺工人进行了一项研究,旨在通过评估一氧化碳的全肺和部分肺导纳来衡量肺的扩散功能。根据辛辛那提分类法,这些工人被分为三组。与先前在一组正常受试者中记录的标准值相比,所有组的一氧化碳全肺导纳平均值均出现下降。仅在第2组和第3组中,部分导纳显示平均值低于正常值,这仅涉及肺泡-毛细血管导纳。对患支气管炎和未患支气管炎的矽肺受试者的部分导纳研究表明,前者的通气和肺泡-毛细血管导纳下降,而后者仅肺泡-毛细血管导纳下降。