Examination of the reliability of the portable calorimeter.

作者信息

Igawa Shoji, Sakamaki Mikako, Miyazaki Masami

机构信息

Department of Healthcare, Nippon Sport Science University, 1221-1, Kamoshida-cho, Aaba-ku, Yokohama 227-0033, Japan.

出版信息

Clin Exp Pharmacol Physiol Suppl. 2002 Oct(29):S13-5.

PMID:12355907
Abstract
  1. The present study was performed in order to determine the reliability of the portable calorimeter. 2. Resting energy expenditure (REE) was measured by two different apparatuses: one was the typical gas analyser, the other was the portable calorimeter. 3. Although there are differences among individuals, unless the subject has been exposed to severe physical activity prior to the measurement, a suitable resting time prior to the measurement of resting metabolic rate is 10 min. 4. For the measurement of resting metabolic rate, fluctuations in respiratory quotient (RQ) are extremely small; there is greater fluctuation due to variations in respiration. Therefore, for the screening of energy consumption, the use of a fixed value for RQ is sufficient when measuring only oxygen uptake. 5. Respiratory fluctuations vary from person to person and it is not possible to make stable measurements in 1 or 2 min. Therefore, a suitable measurement time for resting metabolic rate is from 3 to approximately 6 min. 6. The results indicate that this portable calorimeter is a useful apparatus for measuring REE in the field.
摘要

相似文献

1
Examination of the reliability of the portable calorimeter.
Clin Exp Pharmacol Physiol Suppl. 2002 Oct(29):S13-5.
2
Examination of the reliability of the portable calorimeter.便携式热量计可靠性检测
Clin Exp Pharmacol Physiol. 2002 Oct;29(S4):S13-S15. doi: 10.1046/j.1440-1681.29.s4.7.x.
3
Validation of the VO2000 calorimeter for measuring resting metabolic rate.用于测量静息代谢率的VO2000热量计的验证
Clin Nutr. 2006 Aug;25(4):687-92. doi: 10.1016/j.clnu.2006.01.002. Epub 2006 May 15.
4
Validation of a portable indirect calorimeter (Metavine) for measuring energy expenditure in an elderly population.
Clin Exp Pharmacol Physiol Suppl. 2002 Oct(29):S9-12.
5
Measuring energy expenditure in community-dwelling older adults: are portable methods valid and acceptable?测量社区居住老年人的能量消耗:便携式方法是否有效且可接受?
J Am Diet Assoc. 2008 Mar;108(3):544-8. doi: 10.1016/j.jada.2007.12.012.
6
Hand-held indirect calorimeter offers advantages compared with prediction equations, in a group of overweight women, to determine resting energy expenditures and estimated total energy expenditures during research screening.在一组超重女性中,与预测方程相比,手持式间接热量计在研究筛查期间测定静息能量消耗和估计总能量消耗方面具有优势。
J Am Diet Assoc. 2009 May;109(5):836-45. doi: 10.1016/j.jada.2009.02.016.
7
Resting energy expenditure among Japanese.日本人的静息能量消耗。
Clin Exp Pharmacol Physiol Suppl. 2002 Oct(29):S16-8.
8
A computer-controlled indirect calorimeter for the measurement of energy expenditure in one or two subjects simultaneously.一种计算机控制的间接热量计,用于同时测量一至两名受试者的能量消耗。
Hum Nutr Clin Nutr. 1986 Jul;40(4):315-21.
9
Development and evaluation of a simple calorimeter for the measurement of resting metabolism.一种用于测量静息代谢的简易热量计的研制与评估。
Clin Exp Pharmacol Physiol Suppl. 2002 Oct(29):S2-6.
10
MedGem hand-held indirect calorimeter is valid for resting energy expenditure measurement in healthy children.MedGem手持式间接热量计可有效测量健康儿童的静息能量消耗。
Obesity (Silver Spring). 2006 Oct;14(10):1755-61. doi: 10.1038/oby.2006.202.