Five different suture materials (silk, monofilament nylon, polyglyconate, polyglactin 910, and chromic gut) were placed in the skin and body wall of 10 Doitsu (scaleless) koi (Cyprinus carpio). After seven days the sutures were retrieved from five of the fish in 5 mm and 6 mm punch biopsies, and after 14 days they were retrieved in the same way from the other five. The tissue reactions were evaluated by gross visual inspection and by histological examination. The total inflammatory reaction was graded on a scale from 0 (no inflammation) to 5 (severe inflammation). The synthetic suture materials generally induced a moderate inflammatory reaction that decreased after seven days. After 14 days the superficial reaction to monofilament nylon was substantial, and the tissue reactions to the organic suture materials were slightly greater than the reactions to the synthetics. The inflammatory response to silk was greater after 14 days than after seven, and chromic gut induced a moderately severe inflammatory response after seven days; the chromic gut sutures fell out before the biopsies were taken after 14 days. The organic materials induced intense inflammatory reactions which did not subside if the suture remained in the tissue.
将五种不同的缝合材料(丝线、单丝尼龙、聚甘醇酸、聚乙交酯910和铬制肠线)植入10条德国(无鳞)锦鲤(鲤属)的皮肤和体壁中。7天后,从其中5条鱼身上通过5毫米和6毫米的打孔活检取出缝合线,另外5条鱼在14天后以同样的方式取出缝合线。通过大体视觉检查和组织学检查评估组织反应。总的炎症反应按0(无炎症)至5(严重炎症)的等级进行分级。合成缝合材料通常引起中度炎症反应,7天后炎症反应减轻。14天后,单丝尼龙引起的表面反应较为明显,有机缝合材料引起的组织反应略大于合成材料引起的反应。丝线在14天后引起的炎症反应比7天后更强烈,铬制肠线在7天后引起中度严重的炎症反应;14天后在进行活检前铬制肠线缝合线就脱落了。有机材料引起强烈的炎症反应,如果缝合线留在组织中,炎症反应不会消退。