Suppr超能文献

角膜屈光手术后用于矫正不规则散光的隐形眼镜验配

Contact lens fitting to correct irregular astigmatism after corneal refractive surgery.

作者信息

Alió Jorge L, Belda José I, Artola Alberto, García-Lledó Magdalena, Osman Amr

机构信息

Institutio Oftalmológico de Alicante (Alió, Belda, Artola, García-Lledó, Osman), Alicante, Spain.

出版信息

J Cataract Refract Surg. 2002 Oct;28(10):1750-7. doi: 10.1016/s0886-3350(02)01489-x.

Abstract

PURPOSE

To study a technique of contact lens fitting and its visual results in patients with irregular astigmatism induced by corneal refractive surgery.

SETTING

Department of Cornea and Refractive Surgery, Instituto Oftalmológico de Alicante, Alicante, Spain.

METHODS

This prospective noncomparative study comprised 29 eyes with irregular astigmatism after corneal refractive surgery. Different types of contact lenses were used to correct the astigmatism: hard, gas permeable, hybrid, and toric hydrophilic. Preoperative and postoperative data were analyzed for proper fitting including the preoperative keratometeric reading and corneal ablation zone.

RESULTS

Proper contact lens fitting was achieved in 23 eyes (79.3%). In 6 eyes (20.7%), fitting was not possible despite an improvement in best corrected visual acuity (BCVA). Of the eyes with proper fitting, 14 (60.9%) had rigid gas-permeable lenses (9.80 mm), 6 (26.1%) had hydrophilic lenses (14.00 mm), and 3 (13.0%) had hybrid lenses (14.3 mm). Comparing the BCVA with that with spectacles, 23 eyes (79.3%) gained 2 lines or more of BCVA, 4 (13.8%) gained 1 line, and 2 (6.9%) maintained the same acuity as with spectacles. No eye lost lines of BCVA.

CONCLUSIONS

Results indicate that contact lens fitting is a good-and sometimes the only-alternative for patients with induced irregular astigmatism. Rigid gas-permeable contact lenses provided the best visual performance and patient tolerance.

摘要

目的

研究一种角膜屈光手术后不规则散光患者的隐形眼镜验配技术及其视觉效果。

地点

西班牙阿利坎特市阿利坎特眼科研究所角膜与屈光手术科。

方法

这项前瞻性非对照研究纳入了29只角膜屈光手术后出现不规则散光的眼睛。使用不同类型的隐形眼镜来矫正散光:硬性、透气硬性、混合型和复曲面亲水型。分析术前和术后数据以确保合适的验配,包括术前角膜曲率计读数和角膜消融区。

结果

23只眼睛(79.3%)实现了合适的隐形眼镜验配。6只眼睛(20.7%)尽管最佳矫正视力(BCVA)有所改善,但仍无法实现合适验配。在验配合适的眼睛中,14只(60.9%)佩戴了透气硬性隐形眼镜(9.80毫米),6只(26.1%)佩戴了亲水型隐形眼镜(14.00毫米),3只(13.0%)佩戴了混合型隐形眼镜(14.3毫米)。将BCVA与佩戴眼镜时的情况进行比较,23只眼睛(79.3%)的BCVA提高了2行或更多,4只(13.8%)提高了1行,2只(6.9%)与佩戴眼镜时的视力相同。没有眼睛的BCVA下降。

结论

结果表明,对于诱导性不规则散光患者,隐形眼镜验配是一种良好的——有时是唯一的——选择。透气硬性隐形眼镜提供了最佳的视觉性能和患者耐受性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验