Suppr超能文献

线性偏振近红外光照射对肩关节和踝关节灵活性的影响。

Effect of linear polarized near-infrared light irradiation on flexibility of shoulder and ankle joints.

作者信息

Demura S, Yamaji S, Ikemoto Y

机构信息

Department of Physical Education, Kanazawa University, Kanazawa, Japan.

出版信息

J Sports Med Phys Fitness. 2002 Dec;42(4):438-45.

Abstract

BACKGROUND

There is a possibility that heat stimulus by linear polarized near-infrared light irradiation (PL: Super Lizer HA-30, Tokyo Medical Laboratory) improves the range of joint motion, because the flexibility of soft-part tissues, such as a muscle or a tendon, is improved by increasing the muscle temperature. The purpose of this study was to examine the influence of PL-irradiation on the ranges of shoulder and ankle motions.

EXPERIMENTAL DESIGN

30 healthy young adults (15 males: mean+/-SD, age 19.1+/-0.8 yrs, height 173.3+/-4.6 cm, body mass 68.5+/-8.0 kg and 15 females: mean+/-SD, age 19.2+/-0.7 yrs, height 162.3+/-4.5 cm, body mass 58.1+/-6.6 kg) participated in the experiment under PL-irradiation and no-irradiation (placebo) conditions.

MEASURES

the angles of shoulder and ankle joint motions were measured twice, before and after the PL- and placebo-irradiations. The angle of a motion was defined as the angle connecting 3 points at linearity as follows: for the shoulder, the greater trochanter, acromion, and caput ulnare, and for the ankle, the knee joint, fassa of lateral malleolus and metacarpal bone. Each angle was measured when a subject extended or flexed maximally without support.

RESULTS

The trial-to-trial reliability of each range of joint motion was very high. All parameters in PL-irradiation were significantly larger in postirradiation than pre-irradiation, and the value of postirradiation in PL-irradiation was significantly greater than that for placebo. The ranges of shoulder and ankle motions in placebo-irradiation were also significantly greater in postirradiation than pre-irradiation. Moreover, the change rate for each range of joint motion between pre- and postirradiations was significantly greater in PL-irradiation in both joints. In PL-irradiation, most subject's motions were greater in postirradiation than pre-irradiation, but not in the placebo-irradiation. The effect of PL-irradiation tended to be greater on subjects with a small range of a joint motion.

CONCLUSIONS

It is considered from the present results that the ranges of shoulder and ankle motions became greater with PL-irradiation, and is effective as a warming-up method.

摘要

背景

线性偏振近红外光照射(PL:Super Lizer HA - 30,东京医学实验室)产生的热刺激有可能改善关节活动范围,因为肌肉或肌腱等软组织的柔韧性可通过提高肌肉温度得到改善。本研究旨在探讨PL照射对肩部和踝关节活动范围的影响。

实验设计

30名健康青年成年人(15名男性:平均±标准差,年龄19.1±0.8岁,身高173.3±4.6厘米,体重68.5±8.0千克;15名女性:平均±标准差,年龄19.2±0.7岁,身高162.3±4.5厘米,体重58.1±6.6千克)在PL照射和无照射(安慰剂)条件下参与实验。

测量指标

在PL照射和安慰剂照射前后,对肩部和踝关节活动角度各测量两次。运动角度定义为连接以下三点的直线角度:肩部为大转子、肩峰和尺骨头;踝关节为膝关节、外踝沟和掌骨。每个角度在受试者无支撑最大程度伸展或屈曲时测量。

结果

每个关节活动范围的试验间可靠性非常高。PL照射组所有参数照射后均显著大于照射前,且PL照射组照射后的值显著大于安慰剂组。安慰剂照射组肩部和踝关节活动范围照射后也显著大于照射前。此外,两个关节的PL照射组照射前后各关节活动范围的变化率均显著更大。在PL照射组中,大多数受试者照射后的运动幅度大于照射前,但安慰剂照射组并非如此。PL照射对关节活动范围较小的受试者的效果往往更大。

结论

从目前的结果来看,PL照射可使肩部和踝关节活动范围增大,作为一种热身方法是有效的。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验