Suppr超能文献

The clinical effects of thyroid stunning after diagnostic whole-body scanning with 185 MBq 131I.

作者信息

Lees William, Mansberg Robert, Roberts John, Towson Jocelyn, Chua Elizabeth, Turtle John

机构信息

Department of PET and Nuclear Medicine, Royal Prince Alfred Hospital, Camperdown, NSW 2050, Australia.

出版信息

Eur J Nucl Med Mol Imaging. 2002 Nov;29(11):1421-7. doi: 10.1007/s00259-002-0945-8. Epub 2002 Sep 7.

Abstract

"Thyroid stunning" from diagnostic iodine-131 imaging prior to ablative therapy with (131)I for well-differentiated thyroid carcinoma has been well reported, but documentation of the effect on clinical outcome is sparse. The purpose of this retrospective study was to investigate the clinical effects of stunning. The outcome of (131)I ablative therapy in a group of patients ( n=36) who had diagnostic scans using 185 MBq (5 mCi) of (131)I was compared with that in a group ( n=36) who had diagnostic scans using 740 MBq (20 mCi) of (123)I. Patients were imaged at least 4 weeks after near-total thyroidectomy, prior to their first (131)I ablative therapy. Follow-up imaging was performed every 3-6 months, and further (131)I treatment administered when indicated. A group of patients ( n=36) who proceeded directly to their first therapy dose without a diagnostic scan and were followed up with (123)I was compared with the group who did have a (123)I diagnostic scan prior to the first ablative therapy. The efficacy of therapy was evaluated using ablation of the thyroid, evidenced by absence of uptake in the thyroid bed on the diagnostic scan, as the endpoint. Only 47% of patients in the (131)I diagnostic group had the thyroid gland ablated after a single administration of (131)I therapy, compared with 86% in the (123)I diagnostic group ( P<0.005). Patients who had (131)I diagnostic scans required higher total (131)I therapeutic activity (6.7 GBq or 180 mCi) to ablate the thyroid gland than those in the (123)I diagnostic group (4.4 GBq or 119 mCi). There was no difference in outcome between the group who did and the group who did not have a diagnostic study with (123)I prior to their first ablative therapy. The difference in outcome between the (131)I and the (123)I diagnostic groups demonstrates that the efficacy of (131)I therapy is reduced subsequent to the use of 185 MBq of (131)I for diagnostic imaging. This indicates that the phenomenon of stunning is clinically significant and affects the outcome of therapy.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验