Rapid Commun Mass Spectrom. 2002;16(22):2148-53. doi: 10.1002/rcm.849.

Abstract

We describe a method by which the concentrations of volatile compounds in the headspace of their dilute aqueous solutions in sealed containers can be determined using on-line selected ion flow tube mass spectrometry (SIFT-MS). Thus, the changing number density of the molecules of the volatile compound in the carrier gas of the SIFT-MS instrument is described in terms of its changing flow rate as the pressure in the sealed container decreases during the sampling procedure. It is shown that the best analytical procedure is to determine the mean concentration of the trace gas in the liquid headspace over a given sampling time and relate this to the required concentration, which is the initial equilibrium concentration established before the pressure in the sealed container reduces significantly. To test the validity of this analytical approach, the headspace concentrations of acetaldehyde, ethanol and acetone above aqueous solutions of known concentrations have been determined. Hence, the Henry's Law constants for these compounds have been determined and found to agree with the published values. The confirmation of the quality of this sampling methodology combined with SIFT-MS for the analysis of volatile compounds in liquid headspace paves the way for the rapid analyses of biological liquids such as urine and serum for clinical diagnosis and physiological monitoring.

摘要

我们描述了一种方法,通过该方法可以使用在线选择离子流管质谱法(SIFT-MS)测定密封容器中挥发性化合物稀水溶液顶空中挥发性化合物的浓度。因此,随着采样过程中密封容器内压力降低,SIFT-MS仪器载气中挥发性化合物分子的数密度变化通过其流速变化来描述。结果表明,最佳分析程序是在给定采样时间内测定液体顶空中痕量气体的平均浓度,并将其与所需浓度相关联,所需浓度是密封容器内压力显著降低之前建立的初始平衡浓度。为了检验这种分析方法的有效性,已测定了已知浓度水溶液上方乙醛、乙醇和丙酮的顶空浓度。因此,已确定了这些化合物的亨利定律常数,并发现与已发表的值一致。这种采样方法与SIFT-MS相结合用于分析液体顶空中挥发性化合物的质量得到确认,为快速分析尿液和血清等生物液体以进行临床诊断和生理监测铺平了道路。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验