Impact of graphical user interface screen features on computer task accuracy and speed in a cohort of patients with age-related macular degeneration.

作者信息

Scott Ingrid U, Feuer William J, Jacko Julie A

机构信息

Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami School of Medicine, Miami, Florida 33101, USA.

出版信息

Am J Ophthalmol. 2002 Dec;134(6):857-62. doi: 10.1016/s0002-9394(02)01795-6.

Abstract

PURPOSE

To investigate the impact of graphical user interface screen features on computer task performance in patients with age-related macular degeneration (AMD).

DESIGN

Interventional case series.

METHODS

Eighteen patients with visual impairment due to AMD were recruited from the Bascom Palmer Eye Institute Low Vision Clinic. Each patient underwent evaluation of visual acuity using the Early Treatment Diabetic Retinopathy Study protocol, contrast sensitivity using a Pelli-Robson chart, binocular simultaneous visual field using the Esterman program on an automated perimeter, and color vision using Farnsworth D-15. Each subject then completed computer icon identification tasks while the following screen features of the graphical user interface were varied: size of icons displayed, icon set size (number of icons displayed), and background color. Each patient performed all 125 computer tasks with each of five icon sizes (9.2 mm, 14.6 mm, 23.2 mm, 36.8 mm, 58.3 mm), each of five icon set sizes (2, 3, 4, 5, 6), and each of five different background colors (black, white, red, green, blue) in a randomly ordered fashion. Relationships between computer task performance (accuracy and speed) and graphical user interface screen features were studied.

RESULTS

Icon size and icon set size are significantly associated with computer task accuracy (P <.001), whereas background color is not a significant predictor of task accuracy (P =.63). The impact of icon size on accuracy is nonlinear, with the data indicating that no additional improvement in accuracy is associated with increasing the icon size beyond 23.2 mm. The impact of icon set size on accuracy is linear, with a smaller icon set size significantly associated with greater computer accuracy. A larger icon size is significantly associated with a shorter time to task completion (P =.001); this relationship is largely linearly related to icon size. There was no significant impact of background color (P =.11) or set size (P =.37) on time to task completion.

CONCLUSIONS

Modifications of graphical user interface design may permit improved computer task performance among patients with visual impairment due to AMD.

摘要

目的

研究图形用户界面屏幕特征对年龄相关性黄斑变性(AMD)患者计算机任务表现的影响。

设计

干预性病例系列研究。

方法

从巴斯科姆·帕尔默眼科研究所低视力诊所招募了18名因AMD导致视力受损的患者。每位患者按照早期糖尿病视网膜病变研究方案接受视力评估,使用佩利-罗布森图表评估对比敏感度,使用自动视野计上的埃斯特曼程序评估双眼同时视野,使用法恩斯沃思D-15评估色觉。然后,在改变图形用户界面的以下屏幕特征时,每位受试者完成计算机图标识别任务:显示的图标大小、图标集大小(显示的图标数量)和背景颜色。每位患者以随机顺序对五种图标大小(9.2毫米、14.6毫米、23.2毫米、36.8毫米、58.3毫米)、五种图标集大小(2、3、4、5、6)和五种不同背景颜色(黑色、白色、红色、绿色、蓝色)中的每一种完成所有125项计算机任务。研究了计算机任务表现(准确性和速度)与图形用户界面屏幕特征之间的关系。

结果

图标大小和图标集大小与计算机任务准确性显著相关(P<.001),而背景颜色不是任务准确性的显著预测因素(P=.63)。图标大小对准确性的影响是非线性的,数据表明,图标大小增加到超过23.2毫米后,准确性不会有额外提高。图标集大小对准确性的影响是线性的,较小的图标集大小与更高的计算机准确性显著相关。更大的图标大小与更短的任务完成时间显著相关(P=.001);这种关系在很大程度上与图标大小呈线性相关。背景颜色(P=.11)或图标集大小(P=.37)对任务完成时间没有显著影响。

结论

图形用户界面设计的修改可能会改善因AMD导致视力受损患者的计算机任务表现。