Suppr超能文献

[近视性准分子激光原位角膜磨镶术的对比敏感度函数]

[Contrast sensitivity function in myopic LASIK].

作者信息

Yan Zonghui, Hu Jianrong, Gu Xunqing, Sun Mian, Yang Liqiong

机构信息

Shenzhen Ophthalmology Center, School of Medicine, Jinan University, Shenzhen 518001, China.

出版信息

Zhonghua Yan Ke Za Zhi. 2002 Nov;38(11):677-9.

Abstract

OBJECTIVE

To evaluate near contrast sensitivity function before and after myopic laser in situ keratomileusis (LASIK).

METHODS

With FACT 101 test chart, static near contrast sensitivity was measured in randomly selected 47 subjects (93 eyes) before, 1 month and 6 months after LASIK. The contrast sensitivity was measured at 1.5, 3.0, 6.0, 12.0 and 18.0 cycles per degree (c/d) spatial frequency respectively and made comparison in them.

RESULTS

The patients achieved the mean uncorrected visual acuity (UCVA) of 1.07 +/- 0.18 and 1.12 +/- 0.20 at postoperative 1-month and 6-months respectively. There was a general reduction in near contrast sensitivity in all spatial frequencies at postoperative 1-month when they were compared with the preoperative contrast sensitivity. The difference at 12 and 18 c/d spatial frequency was statistically significant (t test, P < 0.01). By the 6-month visit, all eyes showed a recovery of static contrast sensitivity function. The group of high myopia (preoperative > or = -6.00 D) and group with complaining of glare and halos after the surgery had a higher decrease rate of contrast sensitivity compared with that of the group preoperative < - 6.00 D and the group of patients without such complaints respectively. The differences at 6.0, 12.0 and 18.0 c/d spatial frequency at 1-month visit was statistically significant (t test, P < 0.05).

CONCLUSIONS

The contrast sensitivity function test offers a more sensitive and comprehensive measure of functional vision than does standard Snellen acuity. The near contrast sensitivity in post-LASIK patients at early stage is reduced despite normal visual acuity and this can affect the quality of vision.

摘要

目的

评估准分子激光原位角膜磨镶术(LASIK)前后的近视力对比敏感度功能。

方法

采用FACT 101测试图,对随机选取的47例患者(93只眼)在LASIK术前、术后1个月和6个月分别测量静态近视力对比敏感度。分别在1.5、3.0、6.0、12.0和18.0周/度(c/d)空间频率下测量对比敏感度并进行比较。

结果

患者术后1个月和6个月时的平均裸眼视力(UCVA)分别达到1.07±0.18和1.12±0.20。与术前对比敏感度相比,术后1个月时所有空间频率的近视力对比敏感度普遍下降。在12和18 c/d空间频率下差异有统计学意义(t检验,P<0.01)。到术后6个月时,所有眼的静态对比敏感度功能均恢复。高度近视组(术前≥-6.00 D)和术后主诉眩光和光晕的组与术前<-6.00 D组和无此类主诉的患者组相比,对比敏感度下降率更高。术后1个月时在6.0、12.0和18.0 c/d空间频率下的差异有统计学意义(t检验,P<0.05)。

结论

与标准的斯内伦视力相比,对比敏感度功能测试对视功能提供了更敏感和全面的测量。LASIK术后早期患者尽管视力正常,但近视力对比敏感度降低,这可能会影响视觉质量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验