Nonradioactive cesium, as an analogue of potassium, has been used to label autologous red blood cells for determination of the red cell volume in man. The initial and the equilibration concentrations of cesium are assayed by fluorescent excitation analysis (FEA), using a 600 mCi 241Americium source and a Si(Li) detector with a 1024-channel analyzer. Comparative studies with 51Chromium in 13 rabbits showed good correlation, but the intracellular cesium concentration achieved by simple incubation with 2.6 per cent cesium chloride solution was too low to be of practical value in humans. Incubation of the human red blood cells with 50 mug per milliliter of Nystatin in 2.6 per cent cesium chloride opened reversible "pores" in the red cell membrane which permitted high intracellular cesium labeling without demonstrable red cell damage. The cesium red cell volumes in 11 random human subjects differed from the 51Chromium red cell volumes by only 0.2 +/- 4.5 per cent and 2.5 +/- 7.6 per cent at blood sampling times of 10 minutes and 40 minutes, respectively. Blood cesium levels fell with a clearance half-time of 31.5 hours in 4 rabbits, and 2.4 days in 1 normal human. Fluorescent excitation analysis of cesium-labeled autologous red blood cells permits accurate determination of the red cell volume in man without associated patient radiation, thus making the procedure much more acceptable for children, pregnant women, normal volunteers, and for repeated studies in the same individual.

摘要

非放射性铯作为钾的类似物,已被用于标记自体红细胞,以测定人体红细胞容量。铯的初始浓度和平衡浓度通过荧光激发分析(FEA)测定,使用600毫居里的241镅源和带有1024通道分析仪的硅(锂)探测器。对13只兔子进行的铯与51铬的对比研究显示出良好的相关性,但通过简单地与2.6%的氯化铯溶液孵育所达到的细胞内铯浓度过低,在人体中没有实际应用价值。在2.6%的氯化铯中用每毫升50微克的制霉菌素孵育人红细胞,可在红细胞膜上打开可逆的“孔”,从而允许高细胞内铯标记,且无明显的红细胞损伤。11名随机选取的人体受试者的铯红细胞容量与51铬红细胞容量相比,在采血时间为10分钟和40分钟时,分别仅相差0.2±4.5%和2.5±7.6%。4只兔子的血铯水平下降,清除半衰期为31.5小时,1名正常人的清除半衰期为2.4天。对铯标记的自体红细胞进行荧光激发分析,可在不使患者受到辐射的情况下准确测定人体红细胞容量,因此该方法对儿童、孕妇、正常志愿者以及对同一个体进行重复研究而言更易被接受。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验