Patellar tendon bearing (PTB) and total surface bearing (TSB) sockets have been used respectively in the prosthetic treatment of 20 trans-tibial amputees to investigate the effectiveness of both sockets on prosthetic fitting and rehabilitation. Data analysis showed that prostheses with TSB sockets were lighter than the prostheses with PTB sockets and better suspension was obtained from TSB prosthetic socket (p<0.05). It was also found that weight acceptance on the amputated side advanced to a more normal value with TSB prostheses (p<0.05). There was a statistically significant difference between the two socket types in walking and in other ambulation activities except sitting and standing up from a chair, in favour of the TSB socket (p<0.05). Consequently, due to the outcome of this study it can be said that TSB prosthetic sockets can be used effectively in the rehabilitation of trans-tibial amputees.