Abstract

In order to analyze cerebral blood flow for diagnostic purposes, Indium 113m-DTPA was i.v. injected into seated patients, and time-activity curves were registered by a multifacet gamma camera (Fucks-Knipping) from 8 regions of interest, from the median area and from the right and left side of the head: 3 from the hemisphere, 3 from the brain stem, 2 from the large arteries of the neck. The results from 14 patients with chronic impairment of cerebral blood flow were compared with normal data from 20 healthy individuals. The time activity curves were analyzed for peak-height, mean transit time, and ratio peak to plateau height. The individual parameters were investigated for the degree of their correlation in a multiparameter system. The results from the patients indicated for the different single parameters a non-uniform response. There was also no correlation between the deviation of different parameters, between single pathological parameters and the degree and the site of blood flow impairment. On the other hand, a positive correlation was found between the number of pathological parameters and the degree of blood flow impairment irrespective of the site of its localization. Reason for this result probably is the variable location and degree of blood flow compensation by collaterals, which predominantly are expected at the cerebral base. The data indicate the potential usefulness of the application of the multiparameter analysis to quantitatively detect the degree of impairment of cerebral blood flow without regard to its topography. In this respect, the method, here described, promises to be of clinical value for non-invasive and non-hazardous diagnostic screening of cerebral blood flow.

摘要

为了分析脑血流用于诊断目的,将铟113m - DTPA静脉注射到坐位患者体内,并用多面γ相机(Fucks - Knipping)从8个感兴趣区域、中线区域以及头部右侧和左侧记录时间 - 活性曲线:3个来自半球,3个来自脑干,2个来自颈部大动脉。将14例慢性脑血流受损患者的结果与20名健康个体的正常数据进行比较。分析时间活性曲线的峰值高度、平均通过时间以及峰值与平台高度之比。在多参数系统中研究各个参数的相关程度。患者的结果表明,对于不同的单个参数有不均匀的反应。不同参数的偏差之间、单个病理参数与血流受损程度和部位之间也没有相关性。另一方面,发现病理参数的数量与血流受损程度之间存在正相关,而不考虑其定位部位。该结果的原因可能是侧支循环对血流的代偿位置和程度不同,侧支循环主要出现在脑底部。数据表明多参数分析应用于定量检测脑血流受损程度而不考虑其拓扑结构具有潜在的有用性。在这方面,本文所述方法有望对脑血流进行无创且无害的诊断筛查具有临床价值。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验