Nakazawa Nobuhiro, Wakita Kazuo, Mineura Katsuyoshi, Nakamura Masaru, Fujii Ryou, Nakanishi Hirotomo, Uji Yoko, Matsuura Shirou, Itani Kenji, Kanatsuna Takahiro, Ido Tatsuo, Imahori Yoshio
Nishijin Hospital.
Kaku Igaku. 2002 Nov;39(4):543-8.
Positron emission tomography (PET) radiotracers have very short physical half-lives. It is hard to complete a bacterial endotoxins test prior to release from medical institutes. For endotoxin quantitative determination, limulus amebocyte lysate (LAL) reagent and kinetic-turbidimetry system were previously developed. We investigated the possibility of a short time test by means of positively charged filters. As a result of this study, the effects of positively charged filters on endotoin removal were over 99.5% for [18F]FDG and [18F]NaF, which were contaminated with the indicated concentration of endotoxin. Combining this filter and the kinetic-turbidimetric method, it was possible to complete a bacterial endotoxins test in 5 min prior to the patient's administration. This test should be required prior to release for PET radiopharmaceutical quality control. It has been suggested that this combination is a good method for this purpose.
正电子发射断层扫描(PET)放射性示踪剂的物理半衰期非常短。在从医疗机构放行之前,很难完成细菌内毒素检测。对于内毒素定量测定,先前已开发出鲎试剂和动态比浊法系统。我们研究了使用带正电荷滤器进行短时间检测的可能性。这项研究的结果表明,对于被指定浓度内毒素污染的[18F]FDG和[18F]NaF,带正电荷滤器对内毒素的去除效果超过99.5%。将这种滤器与动态比浊法相结合,可以在患者给药前5分钟内完成细菌内毒素检测。对于PET放射性药物的质量控制,在放行前应进行此项检测。有人认为这种组合是实现此目的的一种好方法。