Suppr超能文献

先前主动脉成形术复位后移位的包裹物导致升主动脉侵蚀。

Dislocated wrap after previous reduction aortoplasty causes erosion of the ascending aorta.

作者信息

Bauer Matthias, Grauhan Onnen, Hetzer Roland

机构信息

Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum Berlin, Berlin, Germany.

出版信息

Ann Thorac Surg. 2003 Feb;75(2):583-4. doi: 10.1016/s0003-4975(02)04338-2.

Abstract

We report a patient with bicuspid aortic valve and dilatation of the ascending aorta who had previous aortic valve replacement and reduction aortoplasty with wrapping. After 4 years, reoperation because of coronary artery disease and paravalvular leakage revealed an erosion of the aortic wall due to dislocation of the wrap. This complication confirms the need for secure anchoring and good fitting of the Dacron wrap to avoid alterations of the underlying aortic wall.

摘要

我们报告了一名患有二叶式主动脉瓣和升主动脉扩张的患者,该患者曾接受主动脉瓣置换术及带包裹物的主动脉缩窄成形术。4年后,因冠状动脉疾病和瓣周漏进行再次手术时发现,包裹物移位导致主动脉壁侵蚀。这一并发症证实了需要将涤纶包裹物牢固固定并良好贴合,以避免主动脉壁发生改变。