Suppr超能文献

使用血管造影和灌注数据的解剖学匹配,评估负荷单光子发射计算机断层扫描心肌灌注成像在一级分支血管分布区域检测冠状动脉疾病的敏感性、特异性和准确性。

Sensitivity, specificity and accuracy of stress SPECT myocardial perfusion imaging for detection of coronary artery disease in the distribution of first-order branch vessels, using an anatomical matching of angiographic and perfusion data.

作者信息

Schwartz J G, Johnson R B, Aepfelbacher F C, Parker J A, Chen L, Azar R R, Parker R A, Danias P G

机构信息

Cardiovascular Division, Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA 02215, USA.

出版信息

Nucl Med Commun. 2003 May;24(5):543-9. doi: 10.1097/00006231-200305000-00010.

Abstract

We sought to investigate the utility of stress single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) for the identification of coronary artery disease (CAD) in the distribution of first-order branch vessels. We evaluated 135 consecutive patients with coronary angiography and stress SPECT MPI. We anatomically matched angiography and SPECT to assess the sensitivity, specificity and accuracy of SPECT MPI for the detection of CAD in the distribution of first-order branches. Subgroup analysis for stress test performance and previous coronary artery bypass grafting (CABG) was also performed. The sensitivity, specificity and accuracy of stress SPECT MPI for the detection of CAD in the distribution of first-order branch vessels were all 67%. For isolated branch vessel CAD, stress SPECT MPI had a sensitivity of 44%. In patients without CABG, the sensitivity, specificity and accuracy for the detection of CAD in the distribution of first-order branch vessels were 71%, 67% and 68%, compared with 60%, 67% and 64% for patients with CABG. The sensitivity for isolated branch vessel CAD was 50% for patients without CABG, but only 29% for patients with CABG. The sensitivity and specificity for CAD in the distribution of branch vessels were similar for all patients for all stress test modalities and heart rate response (sensitivity, 64-69%; specificity, 61-69%). Stress SPECT MPI offers intermediate sensitivity, specificity and accuracy for the detection of CAD in the distribution of first-order coronary artery branch vessels. However, for isolated branch vessel CAD, stress SPECT has a lower sensitivity, particularly in patients with previous CABG.

摘要

我们旨在研究负荷单光子发射计算机断层扫描(SPECT)心肌灌注成像(MPI)在识别一级分支血管分布区域冠状动脉疾病(CAD)方面的效用。我们评估了135例连续接受冠状动脉造影和负荷SPECT MPI检查的患者。我们对造影和SPECT进行解剖学匹配,以评估SPECT MPI在检测一级分支血管分布区域CAD时的敏感性、特异性和准确性。还对负荷试验表现和既往冠状动脉旁路移植术(CABG)进行了亚组分析。负荷SPECT MPI检测一级分支血管分布区域CAD的敏感性、特异性和准确性均为67%。对于孤立分支血管CAD,负荷SPECT MPI的敏感性为44%。在未行CABG的患者中,检测一级分支血管分布区域CAD的敏感性、特异性和准确性分别为71%、67%和68%,而行CABG患者的相应数据为60%、67%和64%。未行CABG患者中孤立分支血管CAD的敏感性为50%,而行CABG患者仅为29%。对于所有患者,所有负荷试验方式和心率反应下,分支血管分布区域CAD的敏感性和特异性相似(敏感性为64 - 69%;特异性为61 - 69%)。负荷SPECT MPI在检测一级冠状动脉分支血管分布区域CAD时具有中等的敏感性、特异性和准确性。然而,对于孤立分支血管CAD,负荷SPECT的敏感性较低,尤其是在既往有CABG的患者中。