Suppr超能文献

单光子发射计算机断层扫描心肌灌注成像(SPECT-MPI)通过基于计算机断层扫描血管造影(CCTA)得出的血流储备分数(FFR)预测功能性显著冠状动脉疾病的诊断性能:来自ACCURACY和VCT001研究的亚分析

The diagnostic performance of SPECT-MPI to predict functional significant coronary artery disease by fractional flow reserve derived from CCTA (FFR): sub-analysis from ACCURACY and VCT001 studies.

作者信息

Nakanishi Rine, Osawa Kazuhiro, Ceponiene Indre, Huth Glenn, Cole Jason, Kim Michael, Nezarat Negin, Rahmani Sina, Li Dong, Gupta Souma, Rogers Campbell, Dailing Christopher, Budoff Matthew J

机构信息

Los Angeles BioMedical Research Institute at Harbor UCLA Medical Center, Torrance, CA, USA.

ThedaCare Cardiovascular Care, Appleton, WI, USA.

出版信息

Int J Cardiovasc Imaging. 2017 Dec;33(12):2067-2072. doi: 10.1007/s10554-017-1207-y. Epub 2017 Jul 11.

Abstract

Although single photon emission computed tomography-myocardial perfusion image (SPECT-MPI) and fractional flow reserve (FFR) derived from coronary computed tomographic angiography (CCTA) (FFR) have permitted functional assessment of coronary artery disease (CAD), the concordance between these modalities has not been well described. The aim of this study is to compare SPECT-MPI and anatomical stenosis by CCTA and invasive coronary angiography to FFR for assessing functional significance of CAD. We identified 62 patients with suspected CAD who underwent ≥64 slice coronary CTA and SPECT-MPI within 3 months. FFR was analyzed from CCTA data using the computational fluid dynamic techniques. The association between SPECT-MPI ischemia and FFR (≤0.80) was evaluated. Out of 62 patients, 186 vessels were evaluated. On a per-vessel analysis, accuracy, sensitivity and specificity of SPECT-MPI to predict FFR ≤ 0.80 was 74.2, 45.0 and 77.7%, respectively. The area under the curve (AUC) by receiver-operating characteristic curve analysis for SPECT-MPI demonstrated a modest performance for predicting FFR ≤ 0.80 (AUC 0.56). Among patients with suspected CAD who were assessed by non-invasive functional modalities, SPECT-MPI showed modest concordance with FFR.

摘要

尽管单光子发射计算机断层扫描心肌灌注成像(SPECT-MPI)以及基于冠状动脉计算机断层血管造影(CCTA)得出的血流储备分数(FFR)已可用于对冠状动脉疾病(CAD)进行功能评估,但这些检查方法之间的一致性尚未得到充分描述。本研究的目的是比较SPECT-MPI、CCTA显示的解剖学狭窄以及有创冠状动脉造影与FFR在评估CAD功能意义方面的差异。我们纳入了62例疑似CAD的患者,这些患者在3个月内接受了≥64层冠状动脉CTA和SPECT-MPI检查。使用计算流体动力学技术从CCTA数据中分析FFR。评估SPECT-MPI缺血与FFR(≤0.80)之间的关联。62例患者共评估了186支血管。在单支血管分析中,SPECT-MPI预测FFR≤0.80的准确性、敏感性和特异性分别为74.2%、45.0%和77.7%。SPECT-MPI的受试者工作特征曲线分析得出的曲线下面积(AUC)显示其在预测FFR≤0.80方面表现一般(AUC 0.56)。在通过非侵入性功能检查方法评估的疑似CAD患者中,SPECT-MPI与FFR的一致性一般。