To determine the blood flow in healthy femoral arteries electromagnetic measurements were made on common femoral, superficial femoral and profunda femoris artery in 20 patients during operation for varicose veins. The values obtained were 239 ml/min, 134 ml/min, and 104 ml/min respectively. These registrations were compared with those achieved during reconstructive arterial surgery. It was found that the average basal flow values from corresponding arteries were rather similar. The flow values registered from femoropopliteal bypass grafts were identical with the flow values from the superficial femoral artery of varicose patients. The papaverine response of the common femoral artery flow was tested in 7 varicose patients. The average increase was 250%. None of the average responses from various arteries during arterial reconstructive surgery reached this value. The papaverine responses in femoropopliteal bypass grafts were closely correlated with the arteriographically estimated outflow potential. The flow values both at rest and during vasodilatation showed a great range in all vessels measured.
为测定健康股动脉的血流量,在20例静脉曲张手术患者术中,对股总动脉、股浅动脉和股深动脉进行了电磁测量。测得的值分别为239毫升/分钟、134毫升/分钟和104毫升/分钟。将这些测量结果与动脉重建手术期间获得的结果进行了比较。发现相应动脉的平均基础流量值相当相似。股腘动脉搭桥移植术测得的流量值与静脉曲张患者股浅动脉的流量值相同。对7例静脉曲张患者的股总动脉血流的罂粟碱反应进行了测试。平均增加量为250%。动脉重建手术期间各动脉的平均反应均未达到该值。股腘动脉搭桥移植术的罂粟碱反应与血管造影估计的流出潜能密切相关。在所有测量的血管中,静息时和血管扩张时的流量值都有很大范围。