The handheld advanced nucleic acid analyzer (HANAA) is a portable real time thermal cycler unit that weighs under 1 kg and uses silicon and platinum-based thermalcycler units to conduct rapid heating and cooling of plastic reaction tubes. Two light emitting diodes (LED) provide greater than 1 mW of electrical power at wavelengths of 490 nm (blue) and 525 nm (green), allowing detection of the dyes FAM and JOE/TAMRA. Results are displayed in real time as bar graphs, and up to three, 4-sample assays can be run on the charge of the 12 V portable battery pack. The HANAA was evaluated for detection of defined Escherichia coli strains, and wild-type colonies isolated from stream water, using PCR for the lac Z and Tir genes. PCR reactions using SYBR Green dye allowed detection of E. coli ATCC 11775 and E. coli O157:H7 cells in under 30 min of assay time; however, background fluorescence associated with dye binding to nonspecific PCR products was present. DNA extracted from three isolates of Bacillus anthracis Ames, linked to a bioterrorism incident in Washington DC in October 2001, were also successfully tested on the HANAA using primers for the vrrA and capA genes. Positive results were observed at 32 and 22 min of assay time, respectively. A TaqMan probe specific to the aroQ gene of Erwinia herbicola was tested on the HANAA and when 500 cells were used as template, positive results were observed after only 7 min of assay time. Background fluorescence associated with the use of the probe was negligible. The HANAA is unique in offering real time PCR in a handheld format suitable for field use; a commercial version of the instrument, offering six reaction chambers, is available as of Fall 2002.
手持式高级核酸分析仪(HANAA)是一种便携式实时热循环仪,重量不到1千克,使用基于硅和铂的热循环仪对塑料反应管进行快速加热和冷却。两个发光二极管(LED)在490纳米(蓝色)和525纳米(绿色)波长下提供大于1毫瓦的电功率,可检测荧光素(FAM)和JOE/TAMRA染料。结果以柱状图实时显示,使用12伏便携式电池组供电时,最多可同时进行三次、每次四个样本的检测。使用针对lac Z和Tir基因的聚合酶链反应(PCR),对HANAA检测特定大肠杆菌菌株以及从溪水中分离的野生型菌落的能力进行了评估。使用SYBR Green染料的PCR反应在不到30分钟的检测时间内即可检测到大肠杆菌ATCC 11775和大肠杆菌O157:H7细胞;然而,存在与染料结合非特异性PCR产物相关的背景荧光。从与2001年10月华盛顿特区一起生物恐怖事件相关的三株炭疽芽孢杆菌Ames菌株中提取的DNA,也使用针对vrrA和capA基因的引物在HANAA上成功进行了检测。分别在32分钟和22分钟的检测时间观察到阳性结果。在HANAA上测试了一种针对草生欧文氏菌aroQ基因的TaqMan探针,当使用500个细胞作为模板时,仅在7分钟的检测时间后就观察到了阳性结果。与使用该探针相关的背景荧光可忽略不计。HANAA的独特之处在于它以手持式形式提供适合现场使用的实时PCR;截至2002年秋季,该仪器的商业版本已上市,有六个反应腔。