Clinical results of automatic slope adaptation in a dual sensor VVIR pacemaker.

作者信息

van Krieken F M, Perrins J P, Sigmund M

机构信息

Vitatron Medical B.V., Dieren, The Netherlands.

出版信息

Pacing Clin Electrophysiol. 1992 Nov;15(11 Pt 2):1815-20. doi: 10.1111/j.1540-8159.1992.tb02974.x.

Abstract

Manual slope programming in rate adaptive pacemakers can be time consuming. This may become worse with dual sensor devices. The remedy is to let the pacemaker automatically learn the slopes. Fast learning replaces initial manual slope programming. Daily learning is a continuous process to determine and optimize slopes during daily life. Both methods are known for a QT sensing pacemaker. Fast learning is known for other single sensor devices. The aim of this study was to follow daily learning in a QT and activity dual sensor pacemaker, starting with factory slope settings. Six patients were studied for about 8 weeks. The daily learning algorithm appeared to be effective, showing the desired regulation processes. It took 2-5 weeks to reach full rate response.

摘要

相似文献

1
Clinical results of automatic slope adaptation in a dual sensor VVIR pacemaker.
Pacing Clin Electrophysiol. 1992 Nov;15(11 Pt 2):1815-20. doi: 10.1111/j.1540-8159.1992.tb02974.x.
3
Clinical observations with a dual sensor rate adaptive single chamber pacemaker.
Pacing Clin Electrophysiol. 1992 Nov;15(11 Pt 2):1821-5. doi: 10.1111/j.1540-8159.1992.tb02975.x.
4
Dual sensor VVIR mode pacing: is it worth it?
Pacing Clin Electrophysiol. 1996 Nov;19(11 Pt 1):1560-7. doi: 10.1111/j.1540-8159.1996.tb03181.x.
7
Cardiac output is a sensitive indicator of difference in exercise performance between single and dual sensor pacemakers.
Pacing Clin Electrophysiol. 1998 Jan;21(1 Pt 1):35-41. doi: 10.1111/j.1540-8159.1998.tb01059.x.
8
One-year follow-up of automatic adaptation of the rate response algorithm of the QT sensing, rate adaptive pacemaker.
Pacing Clin Electrophysiol. 1991 Nov;14(11 Pt 1):1598-605. doi: 10.1111/j.1540-8159.1991.tb02735.x.
9
Multicenter clinical evaluation of a new SSIR pacemaker.
Pacing Clin Electrophysiol. 1992 Nov;15(11 Pt 2):1798-803. doi: 10.1111/j.1540-8159.1992.tb02971.x.
10
Is accurate rate response programming necessary?
Pacing Clin Electrophysiol. 1990 Aug;13(8):1031-44. doi: 10.1111/j.1540-8159.1990.tb02150.x.

引用本文的文献

1
Contemporary issues in rate-adaptive pacing.
Clin Cardiol. 1997 Aug;20(8):726-9. doi: 10.1002/clc.4960200812.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验