Hohnloser S H, Klingenheben T, Zabel M, Schröder F, Just H
University Hospital, Department of Cardiology, Freiburg, Germany.
Pacing Clin Electrophysiol. 1992 Nov;15(11 Pt 2):2211-4. doi: 10.1111/j.1540-8159.1992.tb03049.x.
Heart rate variability was determined from three consecutive Holter recordings performed on days 1, 7, and 28 in 17 normal subjects, in 13 patients with angiographically normal coronary arteries, and in 9 patients with remote myocardial infarctions. Group data of several time and frequency domain measures of heart rate variability were highly reproducible (correlation coefficients 0.629-0.894). However, some individuals exhibited considerably larger day-to-day variations in heart rate variability. Single heart rate indices differed by up to 50% between two Holter recordings. Such potential differences must be considered when repeated heart rate variability determinations are used to assess changes in neurocardiac reflex regulation or effects of therapeutic interventions.
对17名正常受试者、13名冠状动脉造影正常的患者以及9名陈旧性心肌梗死患者,在第1天、第7天和第28天进行连续三次动态心电图记录,以测定心率变异性。心率变异性的几个时域和频域测量指标的组数据具有高度可重复性(相关系数为0.629 - 0.894)。然而,一些个体的心率变异性在日常中表现出相当大的差异。两次动态心电图记录之间的单个心率指标差异高达50%。当使用重复的心率变异性测定来评估神经心反射调节的变化或治疗干预的效果时,必须考虑这种潜在差异。