• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

A micromachined silicon multielectrode for multiunit recording.

作者信息

Spence A J, Hoy R R, Isaacson M S

机构信息

School of Applied and Engineering Physics, Cornell University, Ithaca, NY 14853, USA.

出版信息

J Neurosci Methods. 2003 Jun 30;126(2):119-26. doi: 10.1016/s0165-0270(03)00075-x.

DOI:10.1016/s0165-0270(03)00075-x
PMID:12814836
Abstract

A 16-channel multielectrode was used to record propagating action potentials from multiple units in the ventral nerve cord of the cricket Gryllus bimaculatus. The multielectrode was fabricated using photolithographic and bulk silicon etching techniques. The fabrication differs from standard methods in its use of deep reactive ion etching (DRIE) to form the bulk electrode structure. This technique enables the fabrication of relatively thick (>100 microm), rigid structures whose top surface can have any form of thin film electronics. The multielectrode tested in this paper consists of 16 narrow silicon bridges, 150 microm wide and 350 microm tall, spaced evenly over a centimeter, with passive rectangular gold recording sites on the top surface. The nerve cord was placed perpendicularly across the bridges. In this geometry, the nerve spans a 350 microm deep, 450 microm wide trench between each recording site, permitting adequate isolation of recording sites from each other and a platinum ground plane. Spike templates for eight neurons were formed using principle component analysis and clustering of the concatenated multichannel waveforms. Clean templates were generated from a 40 s recording of stimulus evoked activity. Conduction velocities ranged from 2.59+/-0.05 to 4.99+/-0.12 m/s. Two limitations of extracellular electrode arrays are the resolution of overlapping spikes and relation of discriminated units to known anatomy. The high density, precise positioning, and controlled impedance of recording sites achievable in microfabricated devices such as this one will aid in overcoming these limitations. The rigid devices fabricated using this process offer stable positioning of recording sites over relatively large distances (several millimeters) and are suitable for clamping or squeezing of nerve cords.

摘要

相似文献

1
A micromachined silicon multielectrode for multiunit recording.
J Neurosci Methods. 2003 Jun 30;126(2):119-26. doi: 10.1016/s0165-0270(03)00075-x.
2
Polytrodes: high-density silicon electrode arrays for large-scale multiunit recording.多电极:用于大规模多单元记录的高密度硅电极阵列。
J Neurophysiol. 2005 May;93(5):2987-3000. doi: 10.1152/jn.01023.2004. Epub 2004 Nov 17.
3
A Molecular Perspective on Understanding and Modulating the Performance of Chronic Central Nervous System (CNS) Recording Electrodes从分子角度理解和调控慢性中枢神经系统(CNS)记录电极的性能
4
Unit activity, evoked potentials and slow waves in the rat hippocampus and olfactory bulb recorded with a 24-channel microelectrode.用24通道微电极记录大鼠海马体和嗅球中的单位活动、诱发电位和慢波。
Neuroscience. 1985 Jul;15(3):703-12. doi: 10.1016/0306-4522(85)90072-7.
5
A micromachined silicon sieve electrode for nerve regeneration applications.一种用于神经再生应用的微机械硅筛电极。
IEEE Trans Biomed Eng. 1994 Apr;41(4):305-13. doi: 10.1109/10.284958.
6
A flexible perforated microelectrode array probe for action potential recording in nerve and muscle tissues.一种用于在神经和肌肉组织中记录动作电位的柔性多孔微电极阵列探针。
J Neurosci Methods. 1997 Apr 4;72(2):189-95. doi: 10.1016/s0165-0270(96)02202-9.
7
Recording large-scale neuronal ensembles with silicon probes in the anesthetized rat.在麻醉大鼠中使用硅探针记录大规模神经元集群。
J Vis Exp. 2011 Oct 19(56):3282. doi: 10.3791/3282.
8
Penetrating multichannel stimulation and recording electrodes in auditory prosthesis research.听觉假体研究中的穿透式多通道刺激与记录电极
Hear Res. 2008 Aug;242(1-2):31-41. doi: 10.1016/j.heares.2008.01.010. Epub 2008 Jan 31.
9
In Vivo Observations of Rapid Scattered Light Changes Associated with Neurophysiological Activity与神经生理活动相关的快速散射光变化的体内观察
10
A laser micromachined probe for recording multiple field potentials in the thalamus.
J Neurosci Methods. 2004 Oct 15;139(1):99-109. doi: 10.1016/j.jneumeth.2004.04.022.