Suppr超能文献

纤维增强复合全冠和固定局部义齿:临床报告

Fiber-reinforced composite crowns and FPDs: a clinical report.

作者信息

Behr Michael, Rosentritt Martin, Handel Gerhard

机构信息

Department of Prosthodontics, University of Regensburg, Germany.

出版信息

Int J Prosthodont. 2003 May-Jun;16(3):239-43.

Abstract

PURPOSE

This clinical study reports on the results of single molar crowns, three-unit inlay fixed partial dentures (FPD), and complete-coverage FPDs made of the glass-fiber composite system Targis/Vectris with an observation period up to 4.4 years.

MATERIALS AND METHODS

In total, 38 restorations were inserted in 19 patients. Of these, 17 were adhesively fixed three-unit inlay FPDs, five were conventionally cemented complete-coverage three-unit FPDs, and 16 were single molar crowns (six adhesively, ten conventionally cemented). The mean observation period was 2.5 +/- 1.0 years. Events like fracture of the framework or veneer, loss of cementation, signs of wear, and outward discoloration were noted and rated according to modified Ryge criteria.

RESULTS

During the observation time, neither loss of cementation nor framework fracture were noted. However, six facings (36%) of the inlay FPDs fractured. The number of cases with discoloration or wear increased over time for all types of restorations. The wear culminated in fiber exposure of two molar crowns (24 months) and one inlay FPD (54 months). One of the five complete-coverage FPDs was replaced at the request of the patient (discoloration). The cumulative survival rate after 36 months was estimated to be 82% for molar crowns and 72% for inlay FPDs.

CONCLUSION

Fiber-reinforced composite restorations need further improvement of the veneering composites. Because of the increasing wear, discoloration, fractures of the facings, and fiber exposure, fiber-reinforced composites should only be used for provisional restorations.

摘要

目的

本临床研究报告了采用玻璃纤维复合系统Targis/Vectris制作的单颗磨牙冠、三单位嵌体固定局部义齿(FPD)和全冠固定局部义齿的结果,观察期长达4.4年。

材料与方法

共19例患者植入了38颗修复体。其中,17颗为粘结固定的三单位嵌体FPD,5颗为传统粘结的全冠三单位FPD,16颗为单颗磨牙冠(6颗粘结,10颗传统粘结)。平均观察期为2.5±1.0年。记录框架或贴面骨折、粘结剂脱落、磨损迹象和外部变色等情况,并根据改良的Ryge标准进行评级。

结果

在观察期内,未发现粘结剂脱落或框架骨折。然而,嵌体FPD的6个贴面(36%)发生了骨折。所有类型修复体的变色或磨损病例数随时间增加。磨损最终导致两颗磨牙冠(24个月)和一颗嵌体FPD(54个月)出现纤维暴露。应患者要求,更换了5颗全冠FPD中的1颗(变色)。36个月后的累积生存率估计磨牙冠为82%,嵌体FPD为72%。

结论

纤维增强复合修复体需要进一步改进贴面复合材料。由于磨损增加、变色、贴面骨折和纤维暴露,纤维增强复合材料仅应用于临时修复。